Add to MyChemicals Print Friendly Page
Chemical Datasheet

2,6-DINITROPHENOL

4.1 - Flammable solid 6.1 - Poison
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 573-56-8
  • Flammable Solid
  • Poison
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
data unavailable
General Description
Yellow crystalline solid with a sweet musty odor. Sinks and mixes slowly with water. (USCG, 1999)

Hazards

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
Air & Water Reactions
Mixes slowly with water.
Fire Hazard
Special Hazards of Combustion Products: Dissociation into irritating nitrogen oxides.

Behavior in Fire: Can explode when heated under confinement. (USCG, 1999)
Health Hazard
INHALATION, INGESTION AND SKIN ABSORPTION: Headache, anorexia, nausea, vomiting, abdominal pain, diarrhea, fever, pain in chest, difficult breathing, profuse sweating and thirst, dizziness and fatigue. SKIN: Discoloration and irritation. Corrosive to skin. (USCG, 1999)
Reactivity Profile
2,6-DINITROPHENOL can detonate or explode when heated under confinement (USCG, 1999). Phenols do not behave as organic alcohols, as one might guess from the presence of a hydroxyl (-OH) group in their structure. Instead, they react as weak organic acids. Phenols and cresols are much weaker as acids than common carboxylic acids (phenol has pKa = 9.88). These materials are incompatible with strong reducing substances such as hydrides, nitrides, alkali metals, and sulfides. Flammable gas (H2) is often generated, and the heat of the reaction may ignite the gas. Heat is also generated by the acid-base reaction between phenols and bases.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below. More info about absorbents, including situations to watch out for...

Response Recommendations

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 113 [Flammable Materials (Wet / Desensitized Explosive)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area immediately for at least 100 meters (330 feet) in all directions.

LARGE SPILL: Consider initial evacuation for 500 meters (1/3 mile) in all directions.

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Fire Extinguishing Agents: Water, dry chemical, CO2, foam (USCG, 1999)
Non-Fire Response
Excerpt from ERG Guide 113 [Flammable Materials (Wet / Desensitized Explosive)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material.

SMALL SPILL: Flush area with large amounts of water.

LARGE SPILL: Wet down with water and dike for later disposal. KEEP "WETTED" PRODUCT WET BY SLOWLY ADDING FLOODING QUANTITIES OF WATER. (ERG, 2020)
Protective Clothing
Safety glasses, self-contained breathing apparatus, pro- tective clothing, butyl rubber gloves and protective shoes. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Call a doctor.

INHALATION: Remove from contaminated area. Administer oxygen and artificial respiration if needed.

EYES: Flush with water.

SKIN: Wash with soap and water.

INGESTION: Gastric lavage and saline cathartics.

OTHER: To reduce fever, use cold packs and alcohol baths. (USCG, 1999)

Physical Properties

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C6H4N2O5
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: 147.2°F (USCG, 1999)
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 1.68 (est) (USCG, 1999) - Denser than water; will sink
Boiling Point: data unavailable
Molecular Weight: 184.11 (USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Dinitrophenol, 2,6- (573-56-8) 0.23 mg/m3 2.5 mg/m3 15 mg/m3
(DOE, 2018)

Regulatory Information

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
2,6-Dinitrophenol 573-56-8 10 pounds

(EPA List of Lists, 2022)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.