Chemical Datasheet
SULFURIC ACID, FUMING |
![]() |
Chemical Identifiers
The
Chemical Identifier fields
include common identification numbers, the
NFPA diamond
U.S. Department of Transportation hazard labels, and a general
description of the chemical. The information in CAMEO Chemicals comes
from a variety of
data sources.
CAS Number | UN/NA Number | DOT Hazard Label | USCG CHRIS Code |
---|---|---|---|
|
|
||
NIOSH Pocket Guide | International Chem Safety Card | ||
none |
NFPA 704
data unavailable
General Description
Thick fuming yellow liquid. Density 16.5 lb / gal. Very toxic by inhalation. Corrosive to metals and tissue, quickly causing severe burns. Used to make chemicals, dyes, explosives and in petroleum refining.
Hazards
The
Hazard fields
include
special hazard alerts
air and water
reactions, fire hazards, health hazards, a reactivity profile, and
details about
reactive groups assignments
and
potentially incompatible absorbents.
The information in CAMEO Chemicals comes from a variety of
data sources.
Reactivity Alerts
- Strong Oxidizing Agent
- Known Catalytic Activity
Air & Water Reactions
Fumes in air. Soluble in water; dissolution generates dangerous amounts of heat that can cause localized boiling and spattering of the acidic mixture and generate heavy fumes, mists. During sulfonation of mononitrobenzene with fuming sulfuric acid, a leak from an internal cooling coil permitted water to enter the reaction tank. A violent eruption occurred due to the heat of solution [MCA Case History 944(1963)].
Fire Hazard
Special Hazards of Combustion Products: Toxic and irritating vapors are generated. (USCG, 1999)
Health Hazard
Acid mist is irritating to eyes, nose and throat. Liquid causes severe burns of skin and eyes. (USCG, 1999)
Reactivity Profile
SULFURIC ACID, FUMING reacts as a strong acid, as an oxidizing agent and as a dehydrating agent. Chars wood, sugar and many other organic materials on contact. The heat from these reactions may ignite the wood, sugar or organic matter. May react explosively with acetic acid, acetic anhydride, acetonitrile, acrolein, acrylic acid, acrylonitrile, allyl alcohol, allyl chloride, ammonium hydroxide, aniline, cresol, butyraldehyde, cumene, ethyl acetate, ethylene diamine, ethylene glycol, glyoxal, isoprene, isopropyl alcohol, methyl ethyl ketone, propylene oxide, pyridine, styrene, vinyl acetate; strong bases (sodium hydroxide, potassium hydroxide) or mineral acids (nitric acid, hydrochloric acid, hydrofluoric acid) [Lewis, 3rd ed., 1993, p. 1195]. Mixing in equal molar portions with any of the following substances in a closed container caused the temperature and pressure to increase: 2-aminoethanol, ammonium hydroxide (28%), chlorosulfonic acid, ethylenediamine, ethyleneimine, ethylene cyanohydrin, hydrochloric acid (36%), hydrofluoric acid (48.7%), isopropyl alcohol, nitric acid (70%), 2-nitropropane, propiolactone, propylene oxide, pyridine, styrene monomer, sodium hydroxide, sulfolane, vinyl acetate, vinylidene chloride [NFPA 1991]. Extremely hazardous in contact with carbides, bromates, chlorates, fulminates, picrates, and powdered metals. May induce violent polymerization in polymerizable organic compounds such as allyl chloride. Reacts exothermically with sodium hypochlorite to produce chlorine gas.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents
Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below. More info about absorbents, including situations to watch out for...
- Cellulose-Based Absorbents
- Expanded Polymeric Absorbents
Response Recommendations
The
Response Recommendation fields
include isolation and evacuation distances, as well as recommendations for
firefighting, non-fire response, protective clothing, and first aid. The
information in CAMEO Chemicals comes from a variety of
data sources.
Isolation and Evacuation
Excerpt from ERG Guide 137 [Substances - Water-Reactive - Corrosive]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 1831 datasheet.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 1831 datasheet.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 137 [Substances - Water-Reactive - Corrosive]:
When material is not involved in fire, do not use water on material itself.
SMALL FIRE: Dry chemical or CO2. If it can be done safely, move undamaged containers away from the area around the fire.
LARGE FIRE: Flood fire area with large quantities of water, while knocking down vapors with water fog. If insufficient water supply, responders should withdraw.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Cool containers with flooding quantities of water until well after fire is out. Do not get water inside containers. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)
When material is not involved in fire, do not use water on material itself.
SMALL FIRE: Dry chemical or CO2. If it can be done safely, move undamaged containers away from the area around the fire.
LARGE FIRE: Flood fire area with large quantities of water, while knocking down vapors with water fog. If insufficient water supply, responders should withdraw.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Cool containers with flooding quantities of water until well after fire is out. Do not get water inside containers. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 137 [Substances - Water-Reactive - Corrosive]:
Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Use water spray to reduce vapors; do not put water directly on leak, spill area or inside container. Keep combustibles (wood, paper, oil, etc.) away from spilled material.
SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. Prevent entry into waterways, sewers, basements or confined areas. (ERG, 2024)
Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Use water spray to reduce vapors; do not put water directly on leak, spill area or inside container. Keep combustibles (wood, paper, oil, etc.) away from spilled material.
SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. Prevent entry into waterways, sewers, basements or confined areas. (ERG, 2024)
Protective Clothing
Respirator approved for acid mists; rubber gloves; splashproof goggles; eyewash fountain and safety shower; rubber footwear; face shield. (USCG, 1999)
DuPont Tychem® Suit Fabrics
Tychem® Fabric Legend
QS = Tychem 2000 SFR |
QC = Tychem 2000 |
SL = Tychem 4000 |
C3 = Tychem 5000 |
TF = Tychem 6000 |
TP = Tychem 6000 FR |
RC = Tychem RESPONDER® CSM |
TK = Tychem 10000 |
RF = Tychem 10000 FR |
Testing Details
The fabric permeation data was generated for DuPont by a third party
laboratory. Permeation data for industrial chemicals is obtained per
ASTM F739. Normalized breakthrough times (the time at which the
permeation rate exceeds 0.1 μg/cm2/min) are reported in minutes. All
chemicals have been tested between approximately 20°C and 27°C unless
otherwise stated. All chemicals have been tested at a concentration of
greater than 95% unless otherwise stated.
Chemical warfare agents (Lewisite, Sarin, Soman, Sulfur Mustard, Tabun
and VX Nerve Agent) have been tested at 22°C and 50% relative humidity
per military standard MIL-STD-282. "Breakthrough time" for chemical
warfare agents is defined as the time when the cumulative mass which
permeated through the fabric exceeds the limit in MIL-STD-282 [either
1.25 or 4.0 μg/cm2].
A Caution from DuPont
This information is based upon technical data that DuPont believes to
be reliable on the date issued. It is subject to revision as additional
knowledge and experience are gained. The information reflects
laboratory performance of fabrics, not complete garments, under
controlled conditions. It is intended for informational use by persons
having technical skill for evaluation under their specific end-use
conditions, at their own discretion and risk. It is the user's
responsibility to determine the level of toxicity and the proper
personal protective equipment needed. Anyone intending to use this
information should first verify that the garment selected is suitable
for the intended use. In many cases, seams and closures have shorter
breakthrough times and higher permeation rates than the fabric. If
fabric becomes torn,abraded or punctured, or if seams or closures fail,
or if attached gloves, visors, etc. are damaged, end user should
discontinue use of garment to avoid potential exposure to chemical.
Since conditions of use are outside our control, DuPont makes no
warranties, express or implied, including, without limitation, no
warranties of merchantability or fitness for a particular use and
assume no liability in connection with any use of this information.
This information is not intended as a license to operate under or a
recommendation to infringe any patent, trademark or technical
information of DuPont or others covering any material or its use.
Chemical | CAS Number | State | QS | QC | SL | C3 | TF | TP | RC | TK | RF |
---|---|---|---|---|---|---|---|---|---|---|---|
Oleum (103% (13% free SO3)) | 8014-95-7 | Liquid | 230 | >480 | |||||||
Oleum (20% free SO3) | 8014-95-7 | Liquid | 60 | >480 | >480 | 15*/59 | >480 | ||||
Oleum (30% free SO3) | 8014-95-7 | Liquid | >480 | >480 | |||||||
Oleum (40% free SO3) | 8014-95-7 | Liquid | 455*/468 | imm*/12 | >480 | >480 | >480 | ||||
Oleum (65% free SO3) | 8014-95-7 | Liquid | 15 | 248 | >480 | ||||||
Sulfuric acid fuming (103% (13% free SO3)) | 8014-95-7 | Liquid | 230 | >480 | |||||||
Sulfuric acid fuming (20% free SO3) | 8014-95-7 | Liquid | 60 | >480 | >480 | 15*/59 | >480 | ||||
Sulfuric acid fuming (30% free SO3) | 8014-95-7 | Liquid | >480 | >480 | |||||||
Sulfuric acid fuming (40% free SO3) | 8014-95-7 | Liquid | 455*/468 | imm*/12 | >480 | >480 | >480 | ||||
Sulfuric acid fuming (65% free SO3) | 8014-95-7 | Liquid | 15 | 248 | >480 |
> indicates greater than.
"imm" indicates immediate; having a normalized breakthrough time of 10 minutes or less.
* indicates based on lowest single value.
"imm" indicates immediate; having a normalized breakthrough time of 10 minutes or less.
* indicates based on lowest single value.
Special Warning from DuPont: Tychem® and Tyvek® fabrics should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Only...
...Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T
(with aluminized outer suit) garments are designed and tested to help
reduce burn injury during escape from a flash fire. Users of Tychem®
ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with
aluminized outer suit) garments should not knowingly enter an explosive
environment. Tychem® garments with attached socks must be worn inside
protective outer footwear and are not suitable as outer footwear. These
attached socks do not have adequate durability or slip resistance to be
worn as the outer foot covering.
(DuPont, 2024)
First Aid
INGESTION: have victim drink water or milk; do NOT induce vomiting.
EYES: flush with plenty of water for at least 15 min.; call a doctor.
SKIN: flush with plenty of water. (USCG, 1999)
EYES: flush with plenty of water for at least 15 min.; call a doctor.
SKIN: flush with plenty of water. (USCG, 1999)
Physical Properties
The
Physical Property fields
include properties such as vapor pressure and
boiling point, as well as explosive limits and
toxic exposure thresholds
The information in CAMEO Chemicals comes from a variety of
data sources.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula: |
|
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature:
Not flammable
(USCG, 1999)
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity:
1.91 to 1.97
at 59°F
(USCG, 1999)
Boiling Point: data unavailable
Molecular Weight: data unavailable
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable
AEGLs (Acute Exposure Guideline Levels)
Exposure Period | AEGL-1 | AEGL-2 | AEGL-3 |
---|---|---|---|
10 minutes | 0.2 mg/m3 | 8.7 mg/m3 | 270 mg/m3 |
30 minutes | 0.2 mg/m3 | 8.7 mg/m3 | 200 mg/m3 |
60 minutes | 0.2 mg/m3 | 8.7 mg/m3 | 160 mg/m3 |
4 hours | 0.2 mg/m3 | 8.7 mg/m3 | 110 mg/m3 |
8 hours | 0.2 mg/m3 | 8.7 mg/m3 | 93 mg/m3 |
(NAC/NRC, 2024)
ERPGs (Emergency Response Planning Guidelines)
Chemical | ERPG-1 | ERPG-2 | ERPG-3 |
---|---|---|---|
Sulfuric Acid (Oleum [8014-95-7], Sulfur Trioxide [7446-11-9], and Sulfuric Acid [7664-93-9]) | 2 mg/m3 ![]() |
10 mg/m3 | 120 mg/m3 |

(AIHA, 2022)
PACs (Protective Action Criteria)
Chemical | PAC-1 | PAC-2 | PAC-3 |
---|---|---|---|
Oleum; (fuming Sulfuric acid) (8014-95-7) | 0.2 mg/m3 | 8.7 mg/m3 | 160 mg/m3 |
(DOE, 2024)
Regulatory Information
The
Regulatory Information fields
include information from
the U.S. Environmental Protection Agency's Title III Consolidated List of
Lists,
the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility
Anti-Terrorism Standards,
and the U.S. Occupational Safety and Health Administration's
Process Safety Management of Highly Hazardous Chemicals Standard List
(see more about these
data sources).
EPA Consolidated List of Lists
Regulatory Name | CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ | EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
---|---|---|---|---|---|---|---|
Oleum (fuming sulfuric acid) | 8014-95-7 | 1000 pounds | 10000 pounds | ||||
Sulfuric acid (fuming) | 8014-95-7 | 1000 pounds | 10000 pounds | ||||
Sulfuric acid, mixture with sulfur trioxide | 8014-95-7 | 1000 pounds | 10000 pounds |
(EPA List of Lists, 2024)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
RELEASE | THEFT | SABOTAGE | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Chemical of Interest | CAS Number | Min Conc | STQ | Security Issue |
Min Conc | STQ | Security Issue |
Min Conc | STQ | Security Issue |
Oleum (Fuming Sulfuric acid); [Sulfuric acid, mixture with sulfur trioxide] | 8014-95-7 | 1.00 % | 10000 pounds | toxic |
(CISA, 2007)
OSHA Process Safety Management (PSM) Standard List
Chemical Name | CAS Number | Threshold Quantity (TQ) |
---|---|---|
Oleum (65% to 80% by weight; also called Fuming Sulfuric Acid) | 8014-95-7 | 1000 pounds |
(OSHA, 2019)
Alternate Chemical Names
This section provides a listing of alternate names for this chemical,
including trade names and synonyms.
- FUMING SULFURIC ACID
- OLEUM
- OLEUM (FUMING SULFURIC ACID)
- OLEUM IODISUM
- SULFUR TRIOXIDE, MIXT. CONTAINING
- SULFURIC ACID
- SULFURIC ACID (FUMING)
- SULFURIC ACID FUMING
- SULFURIC ACID, FUMING
- SULFURIC ACID, MIXTURE WITH SULFUR TRIOXIDE
- SULPHURIC ACID, FUMING