Add to MyChemicals Print Friendly Page
Chemical Datasheet

SEC-BUTYL ACETATE

3 - Flammable liquid
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

The Chemical Identifier fields include common identification numbers, the NFPA diamond, U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 105-46-4   (SEC-BUTYL ACETATE)
  • Flammable Liquid
NIOSH Pocket Guide International Chem Safety Card
sec-Butyl acetateexternal link
NFPA 704
Diamond Hazard Value Description
3
1 0
Blue Health 1 Can cause significant irritation.
Red Flammability 3 Can be ignited under almost all ambient temperature conditions.
Yellow Instability 0 Normally stable, even under fire conditions.
White Special
(NFPA, 2010)
General Description
Watery colorless liquid with a pleasant, fruity odor. Floats on water. Produces irritating vapor. (USCG, 1999)

Hazards

The Hazard fields include special hazard alerts, air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
Air & Water Reactions
Highly flammable. Water soluble.
Fire Hazard
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:

HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water. (ERG, 2016)
Health Hazard
Headaches, dizziness, nausea, irritation of respiratory passage and eyes. (USCG, 1999)
Reactivity Profile
SEC-BUTYL ACETATE is an ester. Esters react with acids to liberate heat along with alcohols and acids. Strong oxidizing acids may cause a vigorous reaction that is sufficiently exothermic to ignite the reaction products. Heat is also generated by the interaction of esters with caustic solutions. Flammable hydrogen is generated by mixing esters with alkali metals and hydrides. Dissolves rubber and plastics (USCG, 1999).
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

Response Recommendations

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:

As an immediate precautionary measure, isolate spill or leak area for at least 50 meters (150 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)
Firefighting
Fire Extinguishing Agents Not to Be Used: Water may be ineffective

Fire Extinguishing Agents: Foam, carbon dioxide, or dry chemical (USCG, 1999)
Non-Fire Response
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2016)
Protective Clothing
Skin: Wear appropriate personal protective clothing to prevent skin contact.

Eyes: Wear appropriate eye protection to prevent eye contact.

Wash skin: The worker should immediately wash the skin when it becomes contaminated.

Remove: Work clothing that becomes wet should be immediately removed due to its flammability hazard(i.e. for liquids with flash point < 100°F)

Change: No recommendation is made specifying the need for the worker to change clothing after the work shift. (NIOSH, 2016)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Eye: If this chemical contacts the eyes, immediately wash the eyes with large amounts of water, occasionally lifting the lower and upper lids. Get medical attention immediately. Contact lenses should not be worn when working with this chemical.

Skin: If this chemical contacts the skin, flush the contaminated skin with water promptly. If this chemical penetrates the clothing, immediately remove the clothing and flush the skin with water promptly. If irritation persists after washing, get medical attention.

Breathing: If a person breathes large amounts of this chemical, move the exposed person to fresh air at once. If breathing has stopped, perform mouth-to-mouth resuscitation. Keep the affected person warm and at rest. Get medical attention as soon as possible.

Swallow: If this chemical has been swallowed, get medical attention immediately. (NIOSH, 2016)

Physical Properties

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds. The information in CAMEO Chemicals comes from a variety of data sources.
Chemical Formula:
  • C6H12O2
Flash Point: 62 ° F (USCG, 1999)
Lower Explosive Limit (LEL): 1.7 % (USCG, 1999)
Upper Explosive Limit (UEL): 9.8 % (USCG, 1999)
Autoignition Temperature: data unavailable
Melting Point: -100 ° F (USCG, 1999)
Vapor Pressure: 51.7 mm Hg (USCG, 1999)
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 0.872 at 68 ° F (USCG, 1999)
Boiling Point: 234 ° F at 760 mm Hg (USCG, 1999)
Molecular Weight: 116.16 (USCG, 1999)
Water Solubility: 0.8 % (NIOSH, 2016)
Ionization Potential: 9.91 eV (NIOSH, 2016)
IDLH: 1700 ppm Based on 10% of the lower explosive limit. (NIOSH, 2016)

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Butyl acetate, sec- (105-46-4) 600 ppm 1700 ppm 1-flame icon indicates value is 10-49% of LEL. 10000 ppm 2-flame icon indicates value is 50-99% of LEL. LEL = 17000 ppm
1-flame icon indicates value is 10-49% of LEL.
2-flame icon indicates value is 50-99% of LEL.
(DOE, 2016)

Regulatory Information

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Department of Homeland Security's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
sec-Butyl acetate 105-46-4 5000 pounds

(EPA List of Lists, 2015)

DHS Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.