Add to MyChemicals Print Friendly Page
Chemical Datasheet

DICHLOROPROPANE - DICHLOROPROPENE (MIXTURE)

Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 8003-19-8
none data unavailable
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
Diamond Hazard Value Description
3
3 0
Blue Health 3 Can cause serious or permanent injury.
Red Flammability 3 Can be ignited under almost all ambient temperature conditions.
Yellow Instability 0 Normally stable, even under fire conditions.
White Special
Note: NFPA ratings shown are for 2,3-dichloropropene, CAS number 78-88-6.
(NFPA, 2010)
General Description
Straw to amber liquid with a pungent, garlic-like odor. Sinks and slowly mixes with water. (USCG, 1999)

Hazards

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
Air & Water Reactions
Highly flammable.
Fire Hazard
Special Hazards of Combustion Products: Smoke contains hydrogen chloride and it may contain phosgene; both components are highly toxic gases.

Behavior in Fire: Can react with aluminum, magnesium and their alloys. Can generate highly irritating and explosive vapors. (USCG, 1999)
Health Hazard
Toxic; may be fatal if inhaled, swallowed or absorbed through the skin. Inhalation causes gasping, refusal to breathe and respiratory distress. Contact may cause burns to skin and eyes. Ingestion may cause acute gastrointestinal distress with congestion and edema of the lungs. (USCG, 1999)
Reactivity Profile
Halogenated aliphatic compounds, such as DICHLOROPROPANE - DICHLOROPROPENE, are moderately or very reactive. Halogenated organics generally become less reactive as more of their hydrogen atoms are replaced with halogen atoms. Low molecular weight haloalkanes are highly flammable and can react with some metals to form dangerous products. Materials in this group are incompatible with strong oxidizing and reducing agents. Also, they are incompatible with many amines, nitrides, azo/diazo compounds, alkali metals, and epoxides. Behavior in Fire: Can react with aluminum, magnesium and their alloys. Can generate highly irritating and explosive vapors (USCG, 1999).
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

Response Recommendations

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
No information available.
Firefighting
Fire Extinguishing Agents: Small fires: dry chemicals, CO2, water spray or foam; large fires: water spray, fog or foam. (USCG, 1999)
Non-Fire Response
Neutralizing Agents for Acids and Caustics: Sodium bicarbonate or sand and soda ash mixture. (USCG, 1999)
Protective Clothing
Wear self contained (positive pressure if available) breathing apparatus and full protective clothing. This material will penetrate ordinary rubber protective equipment such as boots and gloves; therefore chemical resistant equipment must be worn. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
INHALATION: Move victim to fresh air. If breathing has stopped, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

EYES: Immediately flush eyes with running water for at least 15 min.; hold eyelids open if neccessary. Continue to flush eyes with water during transport to treatment facilities.

SKIN: Immediately deluge exposed area with water for at least 15 min.; Remove and isolate contaminated clothing and shoes at the site. Wash contaminated area with soap and water.

INGESTION: If victim is conscious, give no more than 2 glasses of water. Induce vomiting either by giving 30 cc (2 tablespoons) Syrup of Ipecac or by touching the back of the throat. If victim is unconscious or having convulsions, do nothing but keep victim quiet and maintain normal body temperature. (USCG, 1999)

Physical Properties

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C3Cl2H6.C3Cl2H4
Flash Point: 67°F (USCG, 1999)
Lower Explosive Limit (LEL): 5.3 % (USCG, 1999)
Upper Explosive Limit (UEL): 14.5 % (USCG, 1999)
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 1.2 (temperature unknown) (USCG, 1999) - Denser than water; will sink
Boiling Point: 217 to 340°F at 760 mmHg (USCG, 1999)
Molecular Weight: data unavailable
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

No PAC information available.

Regulatory Information

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Dichloropropane - Dichloropropene (mixture) 8003-19-8 100 pounds

(EPA List of Lists, 2022)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.