Add to MyChemicals Print Friendly Page
Chemical Datasheet

TETRAETHYL LEAD, LIQUID

6.1 - Poison
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

The Chemical Identifier fields include common identification numbers, the NFPA diamond, U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources..
CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 78-00-2   (TETRAETHYL LEAD)
  • Poison
NFPA 704
Diamond Hazard Value Description
2
3 2
W
Blue Health 3 Can cause serious or permanent injury.
Red Flammability 2 Must be moderately heated or exposed to relatively high ambient temperatures before ignition can occur.
Yellow Instability 2 Readily undergoes violent chemical changes at elevated temperatures and pressures.
White Special W Reacts violently or explosively with water.
(NFPA, 2010)
NIOSH Pocket Guide International Chem Safety Card
Tetraethyl lead (as Pb)external link
General Description
A colorless liquid with a characteristic odor. Flash point 163° F. Density 14 lb / gal. Insoluble in water. Toxic by inhalation and by skin absorption.

Hazards

The Hazard fields include special hazard alerts, air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
Air & Water Reactions
Insoluble in water.
Fire Hazard
May explode in fires. Decomposes slowly at room temperature and more rapidly at elevated temperatures. (EPA, 1998)
Health Hazard
Extremely poisonous; may be fatal if inhaled, swallowed, or absorbed from the skin. Contact may cause burns to skin and eyes. Most symptoms of poisoning are due to the effects of tetraethyllead on the nervous system. (EPA, 1998)
Reactivity Profile
TETRAETHYL LEAD decomposes under UV light. Reacts with fats; reacts violently with oxidizing agents, causing fire and explosion hazards. Attacks rubber [Handling Chemicals Safely 1980. p. 890].
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

Response Recommendations

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

As an immediate precautionary measure, isolate spill or leak area for at least 50 meters (150 feet) in all directions.

SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above.

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)
Firefighting
Fire fighting should be done from an explosive-resistant location. Use water from unmanned monitors and hose-holders to keep fire-exposed containers cool. When stopping leak, use water spray to protect firefighters. Runoff from fire control or dilution water may cause pollution.

Water spray may be used because the material can be cooled below its flash point. (EPA, 1998)
Non-Fire Response
Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

Fully encapsulating, vapor-protective clothing should be worn for spills and leaks with no fire. ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors.

SMALL SPILL: Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2016)
Protective Clothing
Skin: If concentration is >0.1%, wear appropriate personal protective clothing to prevent skin contact.

Eyes: Wear appropriate eye protection to prevent eye contact.

Wash skin: If concentration is >0.1%, the worker should immediately wash the skin when it becomes contaminated.

Remove: When concentration is >0.1% work clothing that becomes wet or significantly contaminated should be removed and replaced.

Change: Workers whose clothing may have become contaminated should change into uncontaminated clothing before leaving the work premise.

Provide: Facilities for quickly drenching the body should be provided (when concentration is >0.1%) within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2016)
DuPont Tychem® Suit Fabrics
Tychem® Fabric Legend
QC = Tychem QC
SL = Tychem SL
TF = Tychem F
TP = Tychem ThermoPro
C3 = Tychem CPF 3
BR = Tychem BR
RC = Tychem Responder® CSM
TK = Tychem TK
RF = Tychem Reflector®
Testing Details
Permeation data obtained per ASTM F739. Normalized breakthrough times (the time at which the permeation rate is equal to 0.1 µg/cm2/min) reported in minutes. All liquid chemicals have been tested between approximately 20°C and 27°C unless otherwise stated. All chemicals have been tested at a concentration of greater than 95% unless otherwise stated. Chemical warfare agents (Lewisite, Sarin, Soman, Sulfur Mustard, Tabun and VX Nerve Agent) have been tested at 22°C and 50% relative humidity per military standard MIL-STD-282.
Normalized Breakthrough Times (in Minutes)
Chemical CAS Number State QC SL TF TP C3 BR RC TK RF
Tetraethyl lead 78-00-2 Liquid >480 >480 >480 >480 >480
> indicates greater than.
A blank cell indicates the fabric has not been tested. The fabric may or may not offer barrier.

Special Warnings from DuPont

  1. Serged and bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present.
  2. CAUTION: This information is based upon technical data that DuPont believes to be reliable. It is subject to revision as additional knowledge and experience are gained. DuPont makes no guarantee of results and assumes no obligation or liability...
    ... in connection with this information. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. The information set forth herein reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. Please contact DuPont for specific data. If fabric becomes torn, abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, we make no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent or technical information of DuPont or others covering any material or its use.

(DuPont, 2016)

First Aid
Warning: Effects may be delayed for hours to days. Caution is advised.

Signs and Symptoms of Acute Tetraethyllead Exposure: Signs and symptoms of acute exposure to tetraethyllead may be severe and include anxiety, irritability, insomnia, violent/frightening dreams, headache, disorientation, hyperexcitability, delusions, and hallucinations. Muscular weakness, ataxia, tremors, convulsions, cerebral edema, and coma may occur. A metallic taste may be noted. Sneezing, bronchitis, and pneumonia may be observed. Bradycardia (slow heart rate), hypotension (low blood pressure), hypothermia, and pallor may also occur. Gastrointestinal symptoms include vomiting and diarrhea. Tetraethyllead may irritate moist skin, eyes, and mucous membranes.

Emergency Life-Support Procedures: Acute exposure to tetraethyllead may require decontamination and life support for the victims. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.

Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to tetraethyllead.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. RUSH to a health care facility.

Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to tetraethyllead.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Remove contaminated clothing as soon as possible.
4. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
5. Wash exposed skin areas THOROUGHLY with soap and water.
6. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
7. RUSH to a health care facility.

Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
2. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
3. Give the victims water or milk: children up to 1 year old, 125 mL (4 oz or 1/2 cup); children 1 to 12 years old, 200 mL (6 oz or 3/4 cup); adults, 250 mL (8 oz or 1 cup). Water or milk should be given only if victims are conscious and alert.
4. Activated charcoal may be administered if victims are conscious and alert. Use 15 to 30 g (1/2 to 1 oz) for children, 50 to 100 g (1-3/4 to 3-1/2 oz) for adults, with 125 to 250 mL (1/2 to 1 cup) of water.
5. Promote excretion by administering a saline cathartic or sorbitol to conscious and alert victims. Children require 15 to 30 g (1/2 to 1 oz) of cathartic; 50 to 100 g (1-3/4 to 3-1/2 oz) is recommended for adults.
6. RUSH to a health care facility. (EPA, 1998)

Physical Properties

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds. The information in CAMEO Chemicals comes from a variety of data sources.
Chemical Formula:
  • Pb(C2H5)4
Flash Point: 200 ° F (EPA, 1998)
Lower Explosive Limit (LEL): 1.8 % (EPA, 1998)
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: 230 ° F (USCG, 1999)
Melting Point: -202 ° F (EPA, 1998)
Vapor Pressure: 0.2 mm Hg at 68 ° F (EPA, 1998)
Vapor Density (Relative to Air): 8.6 (EPA, 1998)
Specific Gravity: 1.653 at 68 ° F (EPA, 1998)
Boiling Point: 392 ° F at 760 mm Hg Decomposes between 230 - 392° F. (EPA, 1998)
Molecular Weight: 323.45 (EPA, 1998)
Water Solubility: less than 1 mg/mL at 70° F (NTP, 1992)
Ionization Potential: 11.10 eV (NIOSH, 2016)
IDLH: 40 mg/m3 (as Pb) (NIOSH, 2016)

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Tetraethyl lead (78-00-2) 0.3 mg/m3 4 mg/m3 40 mg/m3 LEL = 18000 ppm
(DOE, 2016)

Regulatory Information

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists and the U.S. Department of Homeland Security's Chemical Facility Anti-Terrorism Standards (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Lead Compounds N420 & 313
Tetraethyl lead 78-00-2 100 pounds 10 pounds 10 pounds 313c P110

(EPA List of Lists, 2015)

DHS Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.