Add to MyChemicals Print Friendly Page
Chemical Datasheet

OXYGEN DIFLUORIDE

2.3 - Poisonous gas 5.1 - Oxidizer 8 - Corrosive
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 7783-41-7   (OXYGEN DIFLUORIDE)
  • Poison Gas
  • Oxidizer
  • Corrosive
none
NIOSH Pocket Guide International Chem Safety Card
Oxygen difluorideexternal_link
NFPA 704
data unavailable
General Description
A colorless poisonous gas with a strong peculiar odor. Highly toxic by inhalation. Corrosive to skin and eyes. Can explode on contact with water. Decomposes to toxic gaseous fluorine if heated to high temperature. Prolonged exposure of the containers to high heat may result in their violent rupturing and rocketing. Used as an oxidizer for propellants.

Hazards

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
Air & Water Reactions
Violent explosions resulted when a spark was discharged in a 25-70% mixture of oxygen difluoride with oxygen over water [Mellor 2, Supp. 1:191. 1956]. Can explode on contact with water.
Fire Hazard
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:

Substance does not burn but will support combustion. Vapors from liquefied gas are initially heavier than air and spread along ground. These are strong oxidizers and will react vigorously or explosively with many materials including fuels. May ignite combustibles (wood, paper, oil, clothing, etc.). Some will react violently with air, moist air and/or water. Cylinders exposed to fire may vent and release toxic and/or corrosive gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket. (ERG, 2024)
Health Hazard
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:

TOXIC and/or CORROSIVE; may be fatal if inhaled or absorbed through skin. Fire will produce irritating, corrosive and/or toxic gases. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Runoff from fire control or dilution water may cause environmental contamination. (ERG, 2024)
Reactivity Profile
OXYGEN DIFLUORIDE is an oxidizing agent. Mixtures with carbon monoxide, with hydrogen, or with methane explode on sparking [Streng, A. G., Chem. Rev., 1963, 63, p. 610]. May react explosively with adsorbents (silica, alumina, molecular sieves, silica gel) [Streng A. G., Chem. Eng. News, 1965, 43(12), p. 5]; the presence of moisture may render such mixtures shock-sensitive [Metz, F. I., Chem. Eng. News, 1965, 43(7), p. 41]. Gives explosive reactions with diborane, hydrogen sulfide, nitrogen oxide, nitrosyl fluoride, charcoal, sulfur tetrafluoride. Warming of mixtures with halogens, with metal halides, with aluminum chloride, with antimony pentachloride, and with tungsten gives explosions. Ignites on contact with diborane tetrafluoride, phosphorus pentaoxide, red phosphorus, boron, silicon [Bretherick, 5th ed., 1995, p. 1419]. Incompatible with ammonia, arsenic trioxide, chromium trioxide, chlorine in the presence of copper, ozone [Lewis, 3rd ed., 1993, p. 978]. Reacts to incandescence with aluminum, barium, cadmium, magnesium, strontium, zinc, zirconium. Reacts with the alkali metals (lithium, sodium, potassium) [Streng, A. G., Chem. Rev., 1963, 63, p. 611].
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below. More info about absorbents, including situations to watch out for...

Response Recommendations

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.

SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 2190 datasheet.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:

CAUTION: These materials do not burn but will support combustion. Some will react violently with water.

SMALL FIRE: Contain fire and let burn. If fire must be fought, water spray or fog is recommended. Water only; no dry chemical, CO2 or Halon®. Do not get water inside containers. If it can be done safely, move undamaged containers away from the area around the fire. Damaged cylinders should be handled only by specialists.

FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]:

Do not touch or walk through spilled material. Keep combustibles (wood, paper, oil, etc.) away from spilled material. Stop leak if you can do it without risk. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Do not direct water at spill or source of leak. If possible, turn leaking containers so that gas escapes rather than liquid. Prevent entry into waterways, sewers, basements or confined areas. Isolate area until gas has dispersed. Ventilate the area. (ERG, 2024)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Oxygen difluorideexternal link:

Skin: No recommendation is made specifying the need for personal protective equipment for the body.

Eyes: No recommendation is made specifying the need for eye protection.

Wash skin: No recommendation is made specifying the need for washing the substance from the skin (either immediately or at the end of the work shift).

Remove: No recommendation is made specifying the need for removing clothing that becomes wet or contaminated.

Change: No recommendation is made specifying the need for the worker to change clothing after the workshift. (NIOSH, 2024)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Excerpt from NIOSH Pocket Guide for Oxygen difluorideexternal link:

Eye: IRRIGATE IMMEDIATELY - If this chemical contacts the eyes, immediately wash (irrigate) the eyes with large amounts of water, occasionally lifting the lower and upper lids. Get medical attention immediately.

Skin: WATER FLUSH IMMEDIATELY - If this chemical contacts the skin, immediately flush the contaminated skin with water. If this chemical penetrates the clothing, immediately remove the clothing and flush the skin with water. Get medical attention promptly.

Breathing: RESPIRATORY SUPPORT - If a person breathes large amounts of this chemical, move the exposed person to fresh air at once. If breathing has stopped, perform artificial respiration. Keep the affected person warm and at rest. Get medical attention as soon as possible. (NIOSH, 2024)

Physical Properties

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • F2O
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: -371°F (NIOSH, 2024)
Vapor Pressure: greater than 1 atm (NIOSH, 2024)
Vapor Density (Relative to Air): 1.88 (NIOSH, 2024) - Heavier than air; will sink
Specific Gravity: data unavailable
Boiling Point: -230°F at 760 mmHg (NIOSH, 2024)
Molecular Weight: 54 (NIOSH, 2024)
Water Solubility: 0.02 % (NIOSH, 2024)
Ionization Energy/Potential: 13.11 eV (NIOSH, 2024)
IDLH: 0.5 ppm (NIOSH, 2024)

AEGLs (Acute Exposure Guideline Levels)

Final AEGLs for Oxygen difluoride (7783-41-7)
Exposure Period AEGL-1 AEGL-2 AEGL-3
10 minutes NR 0.43 ppm 1.3 ppm
30 minutes NR 0.16 ppm 0.47 ppm
60 minutes NR 0.083 ppm 0.25 ppm
4 hours NR 0.024 ppm 0.071 ppm
8 hours NR 0.013 ppm 0.038 ppm
NR = Not recommended due to insufficient data
(NAC/NRC, 2024)

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Oxygen difluoride; (Fluorine monoxide) (7783-41-7) 0.0075 ppm 0.083 ppm 0.25 ppm
(DOE, 2024)

Regulatory Information

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

No regulatory information available.

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

RELEASE THEFT SABOTAGE
Chemical of Interest CAS Number Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Oxygen difluoride 7783-41-7 0.09 % 15 pounds WME

(CISA, 2007)

OSHA Process Safety Management (PSM) Standard List

Chemical Name CAS Number Threshold Quantity (TQ)
Oxygen Difluoride (Fluorine Monoxide) 7783-41-7 100 pounds

(OSHA, 2019)

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.