Chemical Datasheet
ISOBUTYRONITRILE |
Chemical Identifiers
The
Chemical Identifier fields
include common identification numbers, the
NFPA diamond
U.S. Department of Transportation hazard labels, and a general
description of the chemical. The information in CAMEO Chemicals comes
from a variety of
data sources.
CAS Number | UN/NA Number | DOT Hazard Label | USCG CHRIS Code |
---|---|---|---|
|
|
||
NIOSH Pocket Guide | International Chem Safety Card | ||
Isobutyronitrile | none |
NFPA 704
Diamond | Hazard | Value | Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Health | 3 | Can cause serious or permanent injury. | |||||||||
Flammability | 3 | Can be ignited under almost all ambient temperature conditions. | ||||||||||
Instability | 0 | Normally stable, even under fire conditions. | ||||||||||
Special |
(NFPA, 2010)
General Description
A clear colorless liquid. Flash point 47°F. Less dense than water. Vapors heavier than air. Toxic oxides of nitrogen produced during combustion.
Hazards
The
Hazard fields
include
special hazard alerts
air and water
reactions, fire hazards, health hazards, a reactivity profile, and
details about
reactive groups assignments
and
potentially incompatible absorbents.
The information in CAMEO Chemicals comes from a variety of
data sources.
Reactivity Alerts
- Highly Flammable
Air & Water Reactions
Highly flammable. Slightly soluble in water.
Fire Hazard
Vapor may explode if ignited in an enclosed area. Toxic oxides of nitrogen are produced during combustion. It is a flammable/combustible material and may be ignited by heat, sparks, or flames. Vapors may travel to a source of ignition and flash back. Container may explode in heat of fire. Vapor explosion and poison hazard indoors, outdoors or in sewers. Runoff to sewer may create fire or explosion hazard. Hazardous polymerization may not occur. (EPA, 1998)
Health Hazard
Poisonous; may be fatal if inhaled, swallowed, or absorbed through skin. Contact may cause burns to skin and eyes. (Non-Specific -- Nitriles) Primarily, they are skin and eye irritants. Large doses cause collapse and stop breathing. (EPA, 1998)
Reactivity Profile
ISOBUTYRONITRILE is incompatible with the following: Oxidizers, reducing agents, strong acids & bases (NIOSH, 2024).
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents
No information available.
Response Recommendations
The
Response Recommendation fields
include isolation and evacuation distances, as well as recommendations for
firefighting, non-fire response, protective clothing, and first aid. The
information in CAMEO Chemicals comes from a variety of
data sources.
Isolation and Evacuation
Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind; keep out of low areas. Wear positive pressure breathing apparatus and special protective clothing. Isolate for 1/2 mile in all directions if tank car or truck is involved in fire. Move container from fire area if you can do so without risk. Dike fire control water for later disposal; do not scatter the material. Spray cooling water on containers that are exposed to flames until well after fire is out. Withdraw immediately in case of rising sound from venting safety device or any discoloration of tank due to fire.
Extinguish with dry chemical, carbon dioxide, water spray, foam, or fog. (EPA, 1998)
Extinguish with dry chemical, carbon dioxide, water spray, foam, or fog. (EPA, 1998)
Non-Fire Response
Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors.
SMALL SPILL: Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal. Use clean, non-sparking tools to collect absorbed material.
LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors.
SMALL SPILL: Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal. Use clean, non-sparking tools to collect absorbed material.
LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Isobutyronitrile:
Skin: PREVENT SKIN CONTACT - Wear appropriate personal protective clothing to prevent skin contact.
Eyes: PREVENT EYE CONTACT - Wear appropriate eye protection to prevent eye contact.
Wash skin: WHEN CONTAMINATED - The worker should immediately wash the skin when it becomes contaminated.
Remove: WHEN WET (FLAMMABLE) - Work clothing that becomes wet should be immediately removed due to its flammability hazard (i.e., for liquids with a flash point <100°F).
Change: No recommendation is made specifying the need for the worker to change clothing after the workshift.
Provide:
• EYEWASH - Eyewash fountains should be provided in areas where there is any possibility that workers could be exposed to the substances; this is irrespective of the recommendation involving the wearing of eye protection.
• QUICK DRENCH - Facilities for quickly drenching the body should be provided within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2024)
Skin: PREVENT SKIN CONTACT - Wear appropriate personal protective clothing to prevent skin contact.
Eyes: PREVENT EYE CONTACT - Wear appropriate eye protection to prevent eye contact.
Wash skin: WHEN CONTAMINATED - The worker should immediately wash the skin when it becomes contaminated.
Remove: WHEN WET (FLAMMABLE) - Work clothing that becomes wet should be immediately removed due to its flammability hazard (i.e., for liquids with a flash point <100°F).
Change: No recommendation is made specifying the need for the worker to change clothing after the workshift.
Provide:
• EYEWASH - Eyewash fountains should be provided in areas where there is any possibility that workers could be exposed to the substances; this is irrespective of the recommendation involving the wearing of eye protection.
• QUICK DRENCH - Facilities for quickly drenching the body should be provided within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2024)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Warning: Heart palpitation may occur within minutes after exposure. High doses can stop breathing. Vital signs should be monitored closely. Caution is advised.
Signs and Symptoms of Acute Isobutyronitrile Exposure: Signs and symptoms of acute exposure to isobutyronitrile may include hypertension (high blood pressure) and tachycardia (rapid heart rate), followed by hypotension (low blood pressure) and bradycardia (slow heart rate). Cherry-red (and potentially bloody) mucous membranes, cardiac arrhythmias, and other cardiac abnormalities are common. Cyanosis (blue tint to skin and mucous membranes) may also be found. Tachypnea (rapid respiratory rate) may be followed by respiratory depression. Lung hemorrhage and pulmonary edema may occur. Headache, vertigo (dizziness), agitation, giddiness, salivation, nausea, and vomiting may be followed by combative behavior, convulsions, and coma. Isobutyronitrile is irritating to the skin and mucous membranes. Lacrimation (tearing) and a burning sensation of the mouth and throat are common.
Emergency Life-Support Procedures: Acute exposure to isobutyronitrile may require decontamination and life support for the victims. All exposed persons should be transported to a health care facility as quickly as possible. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.
Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to isobutyronitrile.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with isobutyronitrile- contaminated persons or their gastric contents may result in self- poisoning.
3. RUSH to a health care facility!
4. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to isobutyronitrile.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with isobutyronitrile- contaminated persons or their gastric contents may result in self- poisoning.
3. RUSH to a health care facility!
4. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
5. Remove contaminated clothing as soon as possible.
6. Wash exposed skin areas twice with soap and water.
7. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with isobutyronitrile- contaminated persons or their gastric contents may result in self- poisoning.
2. RUSH to a health care facility!
3. DO NOT induce vomiting or attempt to neutralize!
4. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
5. Activated charcoal is of no value. (EPA, 1998)
Signs and Symptoms of Acute Isobutyronitrile Exposure: Signs and symptoms of acute exposure to isobutyronitrile may include hypertension (high blood pressure) and tachycardia (rapid heart rate), followed by hypotension (low blood pressure) and bradycardia (slow heart rate). Cherry-red (and potentially bloody) mucous membranes, cardiac arrhythmias, and other cardiac abnormalities are common. Cyanosis (blue tint to skin and mucous membranes) may also be found. Tachypnea (rapid respiratory rate) may be followed by respiratory depression. Lung hemorrhage and pulmonary edema may occur. Headache, vertigo (dizziness), agitation, giddiness, salivation, nausea, and vomiting may be followed by combative behavior, convulsions, and coma. Isobutyronitrile is irritating to the skin and mucous membranes. Lacrimation (tearing) and a burning sensation of the mouth and throat are common.
Emergency Life-Support Procedures: Acute exposure to isobutyronitrile may require decontamination and life support for the victims. All exposed persons should be transported to a health care facility as quickly as possible. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.
Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to isobutyronitrile.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with isobutyronitrile- contaminated persons or their gastric contents may result in self- poisoning.
3. RUSH to a health care facility!
4. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to isobutyronitrile.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with isobutyronitrile- contaminated persons or their gastric contents may result in self- poisoning.
3. RUSH to a health care facility!
4. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
5. Remove contaminated clothing as soon as possible.
6. Wash exposed skin areas twice with soap and water.
7. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with isobutyronitrile- contaminated persons or their gastric contents may result in self- poisoning.
2. RUSH to a health care facility!
3. DO NOT induce vomiting or attempt to neutralize!
4. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
5. Activated charcoal is of no value. (EPA, 1998)
Physical Properties
The
Physical Property fields
include properties such as vapor pressure and
boiling point, as well as explosive limits and
toxic exposure thresholds
The information in CAMEO Chemicals comes from a variety of
data sources.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula: |
|
Flash Point:
47°F
(EPA, 1998)
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point:
-96.7°F
(EPA, 1998)
Vapor Pressure:
100 mmHg
at 130°F
(NIOSH, 2024)
Vapor Density (Relative to Air):
2.38
(EPA, 1998)
- Heavier than air; will sink
Specific Gravity:
0.733 to 0.7608
at 68 to 86 °F
(EPA, 1998)
Boiling Point:
219°F
at 760 mmHg
(EPA, 1998)
Molecular Weight:
69.1
(EPA, 1998)
Water Solubility:
Slight
(NIOSH, 2024)
Ionization Energy/Potential: data unavailable
IDLH: data unavailable
AEGLs (Acute Exposure Guideline Levels)
Exposure Period | AEGL-1 | AEGL-2 | AEGL-3 |
---|---|---|---|
10 minutes | NR | 2.5 ppm | 7.6 ppm |
30 minutes | NR | 2.5 ppm | 7.6 ppm |
60 minutes | NR | 2 ppm | 6.1 ppm |
4 hours | NR | 1.3 ppm | 3.8 ppm |
8 hours | NR | 0.83 ppm | 2.5 ppm |
NR = Not recommended due to insufficient data
(NAC/NRC, 2024)
ERPGs (Emergency Response Planning Guidelines)
Chemical | ERPG-1 | ERPG-2 | ERPG-3 |
---|---|---|---|
Isobutyronitrile (78-82-0) | ID | 30 ppm | 100 ppm |
ID = insufficient data.
(AIHA, 2022)
PACs (Protective Action Criteria)
Chemical | PAC-1 | PAC-2 | PAC-3 |
---|---|---|---|
Isobutyronitrile (78-82-0) | 0.18 ppm | 2 ppm | 6.1 ppm |
(DOE, 2024)
Regulatory Information
The
Regulatory Information fields
include information from
the U.S. Environmental Protection Agency's Title III Consolidated List of
Lists,
the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility
Anti-Terrorism Standards,
and the U.S. Occupational Safety and Health Administration's
Process Safety Management of Highly Hazardous Chemicals Standard List
(see more about these
data sources).
EPA Consolidated List of Lists
Regulatory Name | CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ | EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
---|---|---|---|---|---|---|---|
Isobutyronitrile | 78-82-0 | 1000 pounds | 1000 pounds | 20000 pounds | |||
Propanenitrile, 2-methyl- | 78-82-0 | 1000 pounds | 1000 pounds | 20000 pounds |
(EPA List of Lists, 2024)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
RELEASE | THEFT | SABOTAGE | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Chemical of Interest | CAS Number | Min Conc | STQ | Security Issue |
Min Conc | STQ | Security Issue |
Min Conc | STQ | Security Issue |
Isobutyronitrile; [Propanenitrile, 2-methyl-] | 78-82-0 | 1.00 % | 20000 pounds | toxic |
(CISA, 2007)
OSHA Process Safety Management (PSM) Standard List
No regulatory information available.Alternate Chemical Names
This section provides a listing of alternate names for this chemical,
including trade names and synonyms.
- ALPHA-METHYLPROPANENITRILE
- ALPHA-METHYLPROPIONITRILE
- 1-CYANO-1-METHYLETHANE
- 2-CYANOPROPANE
- DIMETHYLACETONITRILE
- IBN
- ISOBUTANENITRILE
- ISOBUTYRONITRILE
- ISOPROPYL CYANIDE
- ISOPROPYL NITRILE
- ISOPROPYLCYANIDE
- 2-METHYLPROPANE NITRILE
- 2-METHYLPROPANENITRILE
- 2-METHYLPROPIONITRILE
- PROPANENITRILE, 2-METHYL-
- PROPANOIC ACID, 2-METHYL-, NITRILE