Add to MyChemicals Print Friendly Page
Chemical Datasheet

ISOBUTYRONITRILE

3 - Flammable liquid 6.1 - Poison
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 78-82-0   (ISOBUTYRONITRILE)
  • Flammable Liquid
  • Poison
NIOSH Pocket Guide International Chem Safety Card
Isobutyronitrileexternal_link none
NFPA 704
Diamond Hazard Value Description
3
3 0
Blue Health 3 Can cause serious or permanent injury.
Red Flammability 3 Can be ignited under almost all ambient temperature conditions.
Yellow Instability 0 Normally stable, even under fire conditions.
White Special
(NFPA, 2010)
General Description
A clear colorless liquid. Flash point 47°F. Less dense than water. Vapors heavier than air. Toxic oxides of nitrogen produced during combustion.

Hazards

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
Air & Water Reactions
Highly flammable. Slightly soluble in water.
Fire Hazard
Vapor may explode if ignited in an enclosed area. Toxic oxides of nitrogen are produced during combustion. It is a flammable/combustible material and may be ignited by heat, sparks, or flames. Vapors may travel to a source of ignition and flash back. Container may explode in heat of fire. Vapor explosion and poison hazard indoors, outdoors or in sewers. Runoff to sewer may create fire or explosion hazard. Hazardous polymerization may not occur. (EPA, 1998)
Health Hazard
Poisonous; may be fatal if inhaled, swallowed, or absorbed through skin. Contact may cause burns to skin and eyes. (Non-Specific -- Nitriles) Primarily, they are skin and eye irritants. Large doses cause collapse and stop breathing. (EPA, 1998)
Reactivity Profile
ISOBUTYRONITRILE is incompatible with the following: Oxidizers, reducing agents, strong acids & bases (NIOSH, 2024).
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

Response Recommendations

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind; keep out of low areas. Wear positive pressure breathing apparatus and special protective clothing. Isolate for 1/2 mile in all directions if tank car or truck is involved in fire. Move container from fire area if you can do so without risk. Dike fire control water for later disposal; do not scatter the material. Spray cooling water on containers that are exposed to flames until well after fire is out. Withdraw immediately in case of rising sound from venting safety device or any discoloration of tank due to fire.

Extinguish with dry chemical, carbon dioxide, water spray, foam, or fog. (EPA, 1998)
Non-Fire Response
Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors.

SMALL SPILL: Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Isobutyronitrileexternal link:

Skin: PREVENT SKIN CONTACT - Wear appropriate personal protective clothing to prevent skin contact.

Eyes: PREVENT EYE CONTACT - Wear appropriate eye protection to prevent eye contact.

Wash skin: WHEN CONTAMINATED - The worker should immediately wash the skin when it becomes contaminated.

Remove: WHEN WET (FLAMMABLE) - Work clothing that becomes wet should be immediately removed due to its flammability hazard (i.e., for liquids with a flash point <100°F).

Change: No recommendation is made specifying the need for the worker to change clothing after the workshift.

Provide:
• EYEWASH - Eyewash fountains should be provided in areas where there is any possibility that workers could be exposed to the substances; this is irrespective of the recommendation involving the wearing of eye protection.
• QUICK DRENCH - Facilities for quickly drenching the body should be provided within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2024)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Warning: Heart palpitation may occur within minutes after exposure. High doses can stop breathing. Vital signs should be monitored closely. Caution is advised.

Signs and Symptoms of Acute Isobutyronitrile Exposure: Signs and symptoms of acute exposure to isobutyronitrile may include hypertension (high blood pressure) and tachycardia (rapid heart rate), followed by hypotension (low blood pressure) and bradycardia (slow heart rate). Cherry-red (and potentially bloody) mucous membranes, cardiac arrhythmias, and other cardiac abnormalities are common. Cyanosis (blue tint to skin and mucous membranes) may also be found. Tachypnea (rapid respiratory rate) may be followed by respiratory depression. Lung hemorrhage and pulmonary edema may occur. Headache, vertigo (dizziness), agitation, giddiness, salivation, nausea, and vomiting may be followed by combative behavior, convulsions, and coma. Isobutyronitrile is irritating to the skin and mucous membranes. Lacrimation (tearing) and a burning sensation of the mouth and throat are common.

Emergency Life-Support Procedures: Acute exposure to isobutyronitrile may require decontamination and life support for the victims. All exposed persons should be transported to a health care facility as quickly as possible. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.

Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to isobutyronitrile.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with isobutyronitrile- contaminated persons or their gastric contents may result in self- poisoning.
3. RUSH to a health care facility!
4. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.

Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to isobutyronitrile.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with isobutyronitrile- contaminated persons or their gastric contents may result in self- poisoning.
3. RUSH to a health care facility!
4. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
5. Remove contaminated clothing as soon as possible.
6. Wash exposed skin areas twice with soap and water.
7. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.

Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with isobutyronitrile- contaminated persons or their gastric contents may result in self- poisoning.
2. RUSH to a health care facility!
3. DO NOT induce vomiting or attempt to neutralize!
4. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
5. Activated charcoal is of no value. (EPA, 1998)

Physical Properties

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C4H7N
Flash Point: 47°F (EPA, 1998)
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: -96.7°F (EPA, 1998)
Vapor Pressure: 100 mmHg at 130°F (NIOSH, 2024)
Vapor Density (Relative to Air): 2.38 (EPA, 1998) - Heavier than air; will sink
Specific Gravity: 0.733 to 0.7608 at 68 to 86 °F (EPA, 1998)
Boiling Point: 219°F at 760 mmHg (EPA, 1998)
Molecular Weight: 69.1 (EPA, 1998)
Water Solubility: Slight (NIOSH, 2024)
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

Final AEGLs for Isobutyronitrile (78-82-0)
Exposure Period AEGL-1 AEGL-2 AEGL-3
10 minutes NR 2.5 ppm 7.6 ppm
30 minutes NR 2.5 ppm 7.6 ppm
60 minutes NR 2 ppm 6.1 ppm
4 hours NR 1.3 ppm 3.8 ppm
8 hours NR 0.83 ppm 2.5 ppm
NR = Not recommended due to insufficient data
(NAC/NRC, 2024)

ERPGs (Emergency Response Planning Guidelines)

Chemical ERPG-1 ERPG-2 ERPG-3
Isobutyronitrile (78-82-0) ID 30 ppm 100 ppm
ID = insufficient data.
(AIHA, 2022)

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Isobutyronitrile (78-82-0) 0.18 ppm 2 ppm 6.1 ppm
(DOE, 2024)

Regulatory Information

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Isobutyronitrile 78-82-0 1000 pounds 1000 pounds 20000 pounds
Propanenitrile, 2-methyl- 78-82-0 1000 pounds 1000 pounds 20000 pounds

(EPA List of Lists, 2024)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

RELEASE THEFT SABOTAGE
Chemical of Interest CAS Number Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Isobutyronitrile; [Propanenitrile, 2-methyl-] 78-82-0 1.00 % 20000 pounds toxic

(CISA, 2007)

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.