Add to MyChemicals Print Friendly Page
Chemical Datasheet

AMMONIUM SULFIDE, SOLUTION

8 - Corrosive 6.1 - Poison 3 - Flammable liquid
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 12135-76-1   (AMMONIUM SULFIDE)
  • Corrosive
  • Poison
  • Flammable Liquid
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
data unavailable
General Description
Ammonium sulfide aqueous solution is a colorless to yellow liquid, with an odor of rotten eggs or ammonia. Can slowly react with water to generate flammable and toxic hydrogen sulfide gas. This reaction is much faster with acid. It may be irritating to skin, eyes and mucous membranes and may cause illness from skin absorption. It may burn and/or emit toxic fumes if heated to high temperatures.

Hazards

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
Air & Water Reactions
Highly flammable. Readily oxidized to be pyrophoric in air [Bretherick 1979 p. 120]. Ammonium sulfide is slowly decomposed by moisture giving off hydrogen sulfide, a toxic and flammable gas. Heat is generated when the pure compound is first dissolved in water.
Fire Hazard
Special Hazards of Combustion Products: Toxic hydrogen sulfide gas is released when solution is heated. If ignited, this will form irritating sulfur dioxide gas. (USCG, 1999)
Health Hazard
Inhalation of 500 ppm for 30 min. produces headaches, dizziness, bronchial pneumonia; 600 ppm for 30 min. can cause death. Ingestion causes severe irritation of mucous membranes and stomach. Contact with liquid causes severe burns of eyes and severe skin irritation. May be absorbed through skin and cause hydrogen sulfide poisoning. (USCG, 1999)
Reactivity Profile
AMMONIUM SULFIDE, SOLUTION is a strongly alkaline aqueous solution. Reacts with acids to generate toxic and flammable gaseous hydrogen sulfide. Reacts with bases to release gaseous ammonia. May react vigorously with oxidizing agents, including inorganic oxoacids, organic peroxides and epoxides. Special Hazards of Combustion Products: Toxic hydrogen sulfide gas is released when solution is heated. If ignited, this will form irritating sulfur dioxide gas (USCG, 1999).
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below. More info about absorbents, including situations to watch out for...

Response Recommendations

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:

Some of these materials may react violently with water.

SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.

LARGE FIRE: Water spray, fog or alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal. Do not get water inside containers.

FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb with earth, sand or other non-combustible material. For hydrazine, absorb with DRY sand or inert absorbent (vermiculite or absorbent pads). Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
Protective Clothing
Self-contained breathing apparatus; rubber or plastic gloves; splash goggles; rubber shoes (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Get medical attention following all overexposures to this compound.

INHALATION: move victim to fresh air; give artificial respiration, oxygen; consult physician.

INGESTION: give large amount of water.

EYES OR SKIN: wash with large quantities of water for 15 min.; consult physician. (USCG, 1999)

Physical Properties

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • (NH4)2S (aqueous)
Flash Point: 72°F (USCG, 1999)
Lower Explosive Limit (LEL): 4 % (hydrogen sulfide) (USCG, 1999)
Upper Explosive Limit (UEL): 46 % (hydrogen sulfide) (USCG, 1999)
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 0.99 to 1.01 at 68°F (USCG, 1999)
Boiling Point: 104°F at 760 mmHg (USCG, 1999)
Molecular Weight: 68.14 (solute) (USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Diammonium sulfide; (Ammonium sulfide) (12135-76-1) 1 ppm 54 ppm 100 ppm
(DOE, 2024)

Regulatory Information

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Ammonium sulfide 12135-76-1 100 pounds

(EPA List of Lists, 2024)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.