Add to MyChemicals Print Friendly Page
Chemical Datasheet

ZINC OXIDE, CRUDE

9 - Miscellaneous hazardous material
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 1314-13-2
  • Class 9
none
NIOSH Pocket Guide International Chem Safety Card
Zinc oxideexternal link
NFPA 704
data unavailable
General Description
Crude zinc oxide is a yellow-gray granular solid with no odor. It is insoluble in water. The primary hazard is the threat posed to the environment. Immediate steps should be taken to limit its spread to the environment. Prolonged inhalation of the dust may result in metal fume fever with symptoms of chills, fever, muscular pain, nausea and vomiting.

Hazards

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
none
Air & Water Reactions
Slowly decomposed (hydrolyzed) in water. Insoluble in water.
Fire Hazard
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:

Some may burn but none ignite readily. Containers may explode when heated. Some may be transported hot. For UN3508, be aware of possible short circuiting as this product is transported in a charged state. (ERG, 2016)
Health Hazard
Exposure Routes: inhalation

Symptoms: Metal fume fever: chills, muscle ache, nausea, fever, dry throat, cough; lassitude (weakness, exhaustion); metallic taste; headache; blurred vision; low back pain; vomiting; malaise (vague feeling of discomfort); chest tightness; dyspnea (breathing difficulty), rales, decreased pulmonary function

Target Organs: respiratory system (NIOSH, 2016)
Reactivity Profile
ZINC OXIDE is insoluble in water. What little solubility it has yields aqueous solutions that are neutral in pH. Intimate mixtures of zinc oxide and chlorinated rubber with or without hydrocarbons or chlorinated solvent react violently, even explosively upon heating [Chem. Trade J., 1962, 151, 672]. Slow addition of zinc oxide to cover the surface of linseed oil varnish caused generation of heat and ignition, [Chem. Trade J., 1933, 92, 278].
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

Response Recommendations

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:

As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above.

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)
Firefighting
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:

SMALL FIRE: Dry chemical, CO2, water spray or regular foam.

LARGE FIRE: Water spray, fog or regular foam. Do not scatter spilled material with high-pressure water streams. Move containers from fire area if you can do it without risk. Dike fire-control water for later disposal.

FIRE INVOLVING TANKS: Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2016)
Non-Fire Response
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:

Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent dust cloud. Avoid inhalation of asbestos dust.

SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.

SMALL SPILL: Pick up with sand or other non-combustible absorbent material and place into containers for later disposal.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Cover powder spill with plastic sheet or tarp to minimize spreading. Prevent entry into waterways, sewers, basements or confined areas. (ERG, 2016)
Protective Clothing
Skin: No recommendation is made specifying the need for personal protective equipment for the body.

Eyes: No recommendation is made specifying the need for eye protection.

Wash skin: No recommendation is made specifying the need for washing the substance from the skin (either immediately or at the end of the work shift).

Remove: No recommendation is made specifying the need for removing clothing that becomes wet or contaminated.

Change: No recommendation is made specifying the need for the worker to change clothing after the work shift. (NIOSH, 2016)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Breathing: If a person breathes large amounts of this chemical, move the exposed person to fresh air at once. If breathing has stopped, perform mouth-to-mouth resuscitation. Keep the affected person warm and at rest. Get medical attention as soon as possible. (NIOSH, 2016)

Physical Properties

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.
Chemical Formula:
  • OZn
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: 3587 ° F (NIOSH, 2016)
Vapor Pressure: 0 mm Hg (approx) (NIOSH, 2016)
Vapor Density (Relative to Air): data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight: 81.4 (NIOSH, 2016)
Water Solubility: 0.0004 % at 64┬░ F (NIOSH, 2016)
Ionization Potential: data unavailable
IDLH: 500 mg/m3 (NIOSH, 2016)

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Zinc oxide (1314-13-2) 10 mg/m3 15 mg/m3 2500 mg/m3
(DOE, 2016)

Regulatory Information

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Department of Homeland Security's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Zinc Compounds N982 & 313

(EPA List of Lists, 2015)

DHS Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.