Chemical Datasheet
URANIUM OXIDES, FLUORIDES, SALTS OR URANATES, NOT IRRADIATED NOR REQUIRING PROTECTIVE SHIELDING |
Chemical Identifiers
The
Chemical Identifier fields
include common identification numbers, the
NFPA diamond
U.S. Department of Transportation hazard labels, and a general
description of the chemical. The information in CAMEO Chemicals comes
from a variety of
data sources.
CAS Number | UN/NA Number | DOT Hazard Label | USCG CHRIS Code |
---|---|---|---|
none |
|
none | |
NIOSH Pocket Guide | International Chem Safety Card | ||
Uranium (insoluble compounds, as U) | none |
NFPA 704
data unavailable
General Description
One of several uranium salts, which are solids of varying colors and appearances. Properties depend on the exact identity of the compound.
Hazards
The
Hazard fields
include
special hazard alerts
air and water
reactions, fire hazards, health hazards, a reactivity profile, and
details about
reactive groups assignments
and
potentially incompatible absorbents.
The information in CAMEO Chemicals comes from a variety of
data sources.
Reactivity Alerts
- Radioactive Material
Air & Water Reactions
No rapid reaction with air. No rapid reaction with water.
Fire Hazard
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
Some of these materials may burn, but most do not ignite readily. Many have cardboard outer packaging; content (physically large or small) can be of many different physical forms. Radioactivity does not change flammability or other properties of materials. (ERG, 2024)
Some of these materials may burn, but most do not ignite readily. Many have cardboard outer packaging; content (physically large or small) can be of many different physical forms. Radioactivity does not change flammability or other properties of materials. (ERG, 2024)
Health Hazard
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
Radiation presents minimal risk to transport workers, emergency response personnel and the public during transportation accidents. Packaging durability increases as potential hazard of radioactive content increases. Very low levels of contained radioactive materials and low radiation levels outside packages result in low risks to people. Damaged packages may release measurable amounts of radioactive material, but the resulting risks are expected to be low. Some radioactive materials cannot be detected by commonly available instruments. Packages do not have RADIOACTIVE I, II, or III labels. Some may have EMPTY labels or may have the word "Radioactive" in the package marking. (ERG, 2024)
Radiation presents minimal risk to transport workers, emergency response personnel and the public during transportation accidents. Packaging durability increases as potential hazard of radioactive content increases. Very low levels of contained radioactive materials and low radiation levels outside packages result in low risks to people. Damaged packages may release measurable amounts of radioactive material, but the resulting risks are expected to be low. Some radioactive materials cannot be detected by commonly available instruments. Packages do not have RADIOACTIVE I, II, or III labels. Some may have EMPTY labels or may have the word "Radioactive" in the package marking. (ERG, 2024)
Reactivity Profile
URANIUM OXIDES, FLUORIDES, SALTS generally behave as acidic inorganic salts. The reaction between bromine trifluoride and oxides of uranium (UO2, UO3, and U3O8) is rapid and quantitative below the boiling point of bromine trifluoride.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents
No information available.
Response Recommendations
The
Response Recommendation fields
include isolation and evacuation distances, as well as recommendations for
firefighting, non-fire response, protective clothing, and first aid. The
information in CAMEO Chemicals comes from a variety of
data sources.
Isolation and Evacuation
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 25 meters (75 feet) in all directions.
LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).
FIRE: When a large quantity of this material is involved in a major fire, consider an initial evacuation distance of 300 meters (1000 feet) in all directions. (ERG, 2024)
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 25 meters (75 feet) in all directions.
LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).
FIRE: When a large quantity of this material is involved in a major fire, consider an initial evacuation distance of 300 meters (1000 feet) in all directions. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
Presence of radioactive material will not influence the fire control processes and should not influence selection of techniques. If it can be done safely, move undamaged containers away from the area around the fire. Do not move damaged packages; move undamaged packages out of fire zone.
SMALL FIRE: Dry chemical, CO2, water spray or regular foam.
LARGE FIRE: Water spray, fog (flooding amounts). (ERG, 2024)
Presence of radioactive material will not influence the fire control processes and should not influence selection of techniques. If it can be done safely, move undamaged containers away from the area around the fire. Do not move damaged packages; move undamaged packages out of fire zone.
SMALL FIRE: Dry chemical, CO2, water spray or regular foam.
LARGE FIRE: Water spray, fog (flooding amounts). (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
Do not touch damaged packages or spilled material. Cover liquid spill with sand, earth or other non-combustible absorbent material. Cover powder spill with plastic sheet or tarp to minimize spreading. (ERG, 2024)
Do not touch damaged packages or spilled material. Cover liquid spill with sand, earth or other non-combustible absorbent material. Cover powder spill with plastic sheet or tarp to minimize spreading. (ERG, 2024)
Protective Clothing
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
Positive pressure self-contained breathing apparatus (SCBA) and structural firefighters' protective clothing will provide adequate protection. (ERG, 2024)
Positive pressure self-contained breathing apparatus (SCBA) and structural firefighters' protective clothing will provide adequate protection. (ERG, 2024)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
Refer to the "General First Aid" section. Specific First Aid: Medical problems take priority over radiological concerns. Use first aid treatment according to the nature of the injury. Do not delay care and transport of a seriously injured person. Injured persons contaminated by contact with released material are not a serious hazard to health care personnel, equipment or facilities. (ERG, 2024)
Refer to the "General First Aid" section. Specific First Aid: Medical problems take priority over radiological concerns. Use first aid treatment according to the nature of the injury. Do not delay care and transport of a seriously injured person. Injured persons contaminated by contact with released material are not a serious hazard to health care personnel, equipment or facilities. (ERG, 2024)
Physical Properties
The
Physical Property fields
include properties such as vapor pressure and
boiling point, as well as explosive limits and
toxic exposure thresholds
The information in CAMEO Chemicals comes from a variety of
data sources.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula: |
|
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight: data unavailable
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH:
10 mg U/m3
; A potential occupational carcinogen.
(NIOSH, 2024)
AEGLs (Acute Exposure Guideline Levels)
No AEGL information available.ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.PACs (Protective Action Criteria)
No PAC information available.Regulatory Information
The
Regulatory Information fields
include information from
the U.S. Environmental Protection Agency's Title III Consolidated List of
Lists,
the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility
Anti-Terrorism Standards,
and the U.S. Occupational Safety and Health Administration's
Process Safety Management of Highly Hazardous Chemicals Standard List
(see more about these
data sources).
EPA Consolidated List of Lists
No regulatory information available.CISA Chemical Facility Anti-Terrorism Standards (CFATS)
No regulatory information available.OSHA Process Safety Management (PSM) Standard List
No regulatory information available.Alternate Chemical Names
This section provides a listing of alternate names for this chemical,
including trade names and synonyms.
- URANIUM OXIDES, FLUORIDES, SALTS OR URANATES, NOT IRRADIATED NOR REQUIRING PROTECTIVE SHIELDING