Chemical Datasheet
URANYL ACETATE |
Chemical Identifiers
The
Chemical Identifier fields
include common identification numbers, the
NFPA diamond
U.S. Department of Transportation hazard labels, and a general
description of the chemical. The information in CAMEO Chemicals comes
from a variety of
data sources.
CAS Number | UN/NA Number | DOT Hazard Label | USCG CHRIS Code |
---|---|---|---|
|
|
||
NIOSH Pocket Guide | International Chem Safety Card | ||
Uranium (soluble compounds, as U) | none |
NFPA 704
data unavailable
General Description
Yellow crystals with a slight odor of vinegar. Density 2.89 g / cm3.
Hazards
The
Hazard fields
include
special hazard alerts
air and water
reactions, fire hazards, health hazards, a reactivity profile, and
details about
reactive groups assignments
and
potentially incompatible absorbents.
The information in CAMEO Chemicals comes from a variety of
data sources.
Reactivity Alerts
- Radioactive Material
Air & Water Reactions
Water soluble, reacting to give a milky solution. The reaction is not hazardous.
Fire Hazard
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
Some of these materials may burn, but most do not ignite readily. Many have cardboard outer packaging; content (physically large or small) can be of many different physical forms. Radioactivity does not change flammability or other properties of materials. (ERG, 2024)
Some of these materials may burn, but most do not ignite readily. Many have cardboard outer packaging; content (physically large or small) can be of many different physical forms. Radioactivity does not change flammability or other properties of materials. (ERG, 2024)
Health Hazard
Inhalation of dust may irritate nose and throat. Contact with eyes causes irritation. (USCG, 1999)
Reactivity Profile
URANYL ACETATE reacts weakly as an acid. Usually does not react as either oxidizing agents or reducing agents but such behavior is not impossible. May catalyze organic reactions.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents
No information available.
Response Recommendations
The
Response Recommendation fields
include isolation and evacuation distances, as well as recommendations for
firefighting, non-fire response, protective clothing, and first aid. The
information in CAMEO Chemicals comes from a variety of
data sources.
Isolation and Evacuation
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 25 meters (75 feet) in all directions.
LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).
FIRE: When a large quantity of this material is involved in a major fire, consider an initial evacuation distance of 300 meters (1000 feet) in all directions. (ERG, 2024)
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 25 meters (75 feet) in all directions.
LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).
FIRE: When a large quantity of this material is involved in a major fire, consider an initial evacuation distance of 300 meters (1000 feet) in all directions. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
Presence of radioactive material will not influence the fire control processes and should not influence selection of techniques. If it can be done safely, move undamaged containers away from the area around the fire. Do not move damaged packages; move undamaged packages out of fire zone.
SMALL FIRE: Dry chemical, CO2, water spray or regular foam.
LARGE FIRE: Water spray, fog (flooding amounts). (ERG, 2024)
Presence of radioactive material will not influence the fire control processes and should not influence selection of techniques. If it can be done safely, move undamaged containers away from the area around the fire. Do not move damaged packages; move undamaged packages out of fire zone.
SMALL FIRE: Dry chemical, CO2, water spray or regular foam.
LARGE FIRE: Water spray, fog (flooding amounts). (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 161 [Radioactive Materials (Low Level Radiation)]:
Do not touch damaged packages or spilled material. Cover liquid spill with sand, earth or other non-combustible absorbent material. Cover powder spill with plastic sheet or tarp to minimize spreading. (ERG, 2024)
Do not touch damaged packages or spilled material. Cover liquid spill with sand, earth or other non-combustible absorbent material. Cover powder spill with plastic sheet or tarp to minimize spreading. (ERG, 2024)
Protective Clothing
Approved dust respirator; goggles or face shield; protective clothing (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Get medical attention after all exposures to this compound.
INHALATION: move to fresh air.
INGESTION: give large amount of water; induce vomiting.
EYES: flush with water for at least 15 min.
SKIN: flush with water. (USCG, 1999)
INHALATION: move to fresh air.
INGESTION: give large amount of water; induce vomiting.
EYES: flush with water for at least 15 min.
SKIN: flush with water. (USCG, 1999)
Physical Properties
The
Physical Property fields
include properties such as vapor pressure and
boiling point, as well as explosive limits and
toxic exposure thresholds
The information in CAMEO Chemicals comes from a variety of
data sources.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula: |
|
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity:
2.89
at 68°F
(USCG, 1999)
- Denser than water; will sink
Boiling Point: data unavailable
Molecular Weight:
424.2
(USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH:
10 mg U/m3
; A potential occupational carcinogen.
(NIOSH, 2024)
AEGLs (Acute Exposure Guideline Levels)
No AEGL information available.ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.PACs (Protective Action Criteria)
Chemical | PAC-1 | PAC-2 | PAC-3 |
---|---|---|---|
Uranyl acetate; (Uranium oxyacetate) (541-09-3) | 0.98 mg/m3 | 5.5 mg/m3 | 33 mg/m3 |
(DOE, 2024)
Regulatory Information
The
Regulatory Information fields
include information from
the U.S. Environmental Protection Agency's Title III Consolidated List of
Lists,
the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility
Anti-Terrorism Standards,
and the U.S. Occupational Safety and Health Administration's
Process Safety Management of Highly Hazardous Chemicals Standard List
(see more about these
data sources).
EPA Consolidated List of Lists
Regulatory Name | CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ | EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
---|---|---|---|---|---|---|---|
Uranyl acetate | 541-09-3 | 100 pounds |
(EPA List of Lists, 2024)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
No regulatory information available.OSHA Process Safety Management (PSM) Standard List
No regulatory information available.Alternate Chemical Names
This section provides a listing of alternate names for this chemical,
including trade names and synonyms.
- BIS (ACETATE) DIOXOURANIUM
- BIS(ACETATO)DIOXOURANIUM
- DIACETATODIOXOURANIUM
- URANIUM ACETATE
- URANIUM ACETATE DIHYDRATE
- URANIUM DIACETATE DIOXIDE
- URANIUM OXYACETATE
- URANIUM OXYACETATE DIHYDRATE
- URANIUM, BIS(ACETATO)DIOXO-
- URANIUM, BIS(ACETATO-O)DIOXO-, (T-4)-
- URANYL ACETATE
- URANYL ACETATE (UO2(OAC)2)
- URANYL ACETATE DIHYDRATE
- URANYL DIACETATE
- URANYL(2+) ACETATE