Chemical Datasheet
TETRAETHYL LEAD, LIQUID |
|
|||||||||
Chemical Identifiers
UN/NA Number - The United Nations-North America number (also called UN number or DOT number). 4-digit number identifying an individual chemical or group of chemicals with similar characteristics. Required on shipping papers; often shown on placards or labels. This numbering system was developed by the U.S. Department of Transportation, and then became the UN standard system for classifying hazardous materials.
CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.
CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.
DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.
NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and reactivity hazards, along with special hazards such as water- and air-reactivity. (The NFPA 704 diamond is also shown at the top of the datasheet.) See a guide to the NFPA diamond.
General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.
List of data sources.
CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.
CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.
DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.
NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and reactivity hazards, along with special hazards such as water- and air-reactivity. (The NFPA 704 diamond is also shown at the top of the datasheet.) See a guide to the NFPA diamond.
General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.
List of data sources.
| UN/NA Number | CAS Number | CHRIS Code | DOT Hazard Label |
|---|---|---|---|
|
|
| NFPA 704: |
|
General Description
A colorless liquid with a characteristic odor. Flash point 200°F. Density 14 lb / gal. Insoluble in water. Toxic by inhalation and by skin absorption.
Hazards
Reactivity Alerts - Special alerts if the chemical is especially reactive
(see list of reactivity alerts).
Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.
Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).
Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).
Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).
Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.
List of data sources.
Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.
Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).
Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).
Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).
Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.
List of data sources.
Reactivity Alerts
none
Air & Water Reactions
Insoluble in water.
Fire Hazard
May explode in fires. Decomposes slowly at room temperature and more rapidly at elevated temperatures. (EPA, 1998)
Health Hazard
Extremely poisonous; may be fatal if inhaled, swallowed, or absorbed from the skin. Contact may cause burns to skin and eyes. Most symptoms of poisoning are due to the effects of tetraethyllead on the nervous system. (EPA, 1998)
Reactivity Profile
TETRAETHYL LEAD decomposes under UV light. Reacts with fats; reacts violently with oxidizing agents, causing fire and explosion hazards. Attacks rubber [Handling Chemicals Safely 1980. p. 890].
Belongs to the Following Reactive Group(s)
Response Recommendations
Firefighting - Response recommendations if the chemical is on fire (or near a fire).
Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).
Protective Clothing - Recommendations for protective gear and, in some cases, a table of breakthrough times for protective materials.
First Aid - Recommended first aid treatment for people exposed to the chemical.
List of data sources.
Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).
Protective Clothing - Recommendations for protective gear and, in some cases, a table of breakthrough times for protective materials.
First Aid - Recommended first aid treatment for people exposed to the chemical.
List of data sources.
Firefighting
Fire fighting should be done from an explosive-resistant location. Use water from unmanned monitors and hose-holders to keep fire-exposed containers cool. When stopping leak, use water spray to protect firefighters. Runoff from fire control or dilution water may cause pollution.
Water spray may be used because the material can be cooled below its flash point. (EPA, 1998)
Water spray may be used because the material can be cooled below its flash point. (EPA, 1998)
Non-Fire Response
Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers. Build dikes to contain flow as necessary. Attempt to stop leak if without undue personnel hazard. Use water spray to knock-down vapors. Land spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid material. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Absorb bulk liquid with fly ash, cement powder, or commercial sorbents. Water spill: Use natural deep water pockets, excavated lagoons, or sand bag barriers to trap material at bottom. If dissolved, in region of 10 ppm or greater concentration, apply activated carbon at ten times the spilled amount. Neutralize with agricultural lime (CaO), crushed limestone (CaCO3), or sodium bicarbonate (NaHCO3). Adjust pH to neutral (pH=7). Remove trapped material with suction hoses. Use mechanical dredges or lifts to remove immobilized masses of pollutants and precipitates. (AAR, 2003)
Protective Clothing
Skin: If concentration is >0.1%, wear appropriate personal protective clothing to prevent skin contact.
Eyes: Wear appropriate eye protection to prevent eye contact.
Wash skin: If concentration is >0.1%, the worker should immediately wash the skin when it becomes contaminated.
Remove: When concentration is >0.1% work clothing that becomes wet or significantly contaminated should be removed and replaced.
Change: Workers whose clothing may have become contaminated should change into uncontaminated clothing before leaving the work premise.
Provide: Facilities for quickly drenching the body should be provided (when concentration is >0.1%) within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2003)
Eyes: Wear appropriate eye protection to prevent eye contact.
Wash skin: If concentration is >0.1%, the worker should immediately wash the skin when it becomes contaminated.
Remove: When concentration is >0.1% work clothing that becomes wet or significantly contaminated should be removed and replaced.
Change: Workers whose clothing may have become contaminated should change into uncontaminated clothing before leaving the work premise.
Provide: Facilities for quickly drenching the body should be provided (when concentration is >0.1%) within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2003)
_____Dupont Average Standardized Breakthrough Times_____
(for TETRAETHYL LEAD)
Tychem® BR
greater than 480 min. (concentration: 95+%)
Tychem® CPF3
greater than 480 min. (concentration: 100%)
Tychem® LV
greater than 480 min. (concentration: 95+%)
Tychem® Responder®
greater than 480 min. (concentration: 63%)
Tychem® Responder® CSM
greater than 480 min. (concentration: 63%)
Tychem® TK
greater than 480 min. (concentration: 95+%) (DuPont, 2008)
Copyrighted information of E.I. du Pont de Nemours and Company. Tychem® is a registered trademark of E.I. du Pont de Nemours and Company.
First Aid
Warning: Effects may be delayed for hours to days. Caution is advised.
Signs and Symptoms of Acute Tetraethyllead Exposure: Signs and symptoms of acute exposure to tetraethyllead may be severe and include anxiety, irritability, insomnia, violent/frightening dreams, headache, disorientation, hyperexcitability, delusions, and hallucinations. Muscular weakness, ataxia, tremors, convulsions, cerebral edema, and coma may occur. A metallic taste may be noted. Sneezing, bronchitis, and pneumonia may be observed. Bradycardia (slow heart rate), hypotension (low blood pressure), hypothermia, and pallor may also occur. Gastrointestinal symptoms include vomiting and diarrhea. Tetraethyllead may irritate moist skin, eyes, and mucous membranes.
Emergency Life-Support Procedures: Acute exposure to tetraethyllead may require decontamination and life support for the victims. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.
Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to tetraethyllead.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. RUSH to a health care facility.
Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to tetraethyllead.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Remove contaminated clothing as soon as possible.
4. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
5. Wash exposed skin areas THOROUGHLY with soap and water.
6. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
7. RUSH to a health care facility.
Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
2. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
3. Give the victims water or milk: children up to 1 year old, 125 mL (4 oz or 1/2 cup); children 1 to 12 years old, 200 mL (6 oz or 3/4 cup); adults, 250 mL (8 oz or 1 cup). Water or milk should be given only if victims are conscious and alert.
4. Activated charcoal may be administered if victims are conscious and alert. Use 15 to 30 g (1/2 to 1 oz) for children, 50 to 100 g (1-3/4 to 3-1/2 oz) for adults, with 125 to 250 mL (1/2 to 1 cup) of water.
5. Promote excretion by administering a saline cathartic or sorbitol to conscious and alert victims. Children require 15 to 30 g (1/2 to 1 oz) of cathartic; 50 to 100 g (1-3/4 to 3-1/2 oz) is recommended for adults.
6. RUSH to a health care facility. (EPA, 1998)
Signs and Symptoms of Acute Tetraethyllead Exposure: Signs and symptoms of acute exposure to tetraethyllead may be severe and include anxiety, irritability, insomnia, violent/frightening dreams, headache, disorientation, hyperexcitability, delusions, and hallucinations. Muscular weakness, ataxia, tremors, convulsions, cerebral edema, and coma may occur. A metallic taste may be noted. Sneezing, bronchitis, and pneumonia may be observed. Bradycardia (slow heart rate), hypotension (low blood pressure), hypothermia, and pallor may also occur. Gastrointestinal symptoms include vomiting and diarrhea. Tetraethyllead may irritate moist skin, eyes, and mucous membranes.
Emergency Life-Support Procedures: Acute exposure to tetraethyllead may require decontamination and life support for the victims. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.
Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to tetraethyllead.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. RUSH to a health care facility.
Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to tetraethyllead.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Remove contaminated clothing as soon as possible.
4. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
5. Wash exposed skin areas THOROUGHLY with soap and water.
6. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
7. RUSH to a health care facility.
Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
2. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
3. Give the victims water or milk: children up to 1 year old, 125 mL (4 oz or 1/2 cup); children 1 to 12 years old, 200 mL (6 oz or 3/4 cup); adults, 250 mL (8 oz or 1 cup). Water or milk should be given only if victims are conscious and alert.
4. Activated charcoal may be administered if victims are conscious and alert. Use 15 to 30 g (1/2 to 1 oz) for children, 50 to 100 g (1-3/4 to 3-1/2 oz) for adults, with 125 to 250 mL (1/2 to 1 cup) of water.
5. Promote excretion by administering a saline cathartic or sorbitol to conscious and alert victims. Children require 15 to 30 g (1/2 to 1 oz) of cathartic; 50 to 100 g (1-3/4 to 3-1/2 oz) is recommended for adults.
6. RUSH to a health care facility. (EPA, 1998)
Physical Properties
This section contains physical properties, flammability limits, and toxic thresholds for this chemical (see
definitions of each property).
More property data is available for common chemicals.
Guide to toxic levels of concern (AEGLs, ERPGs, TEELs, and IDLH).
List of data sources.
Guide to toxic levels of concern (AEGLs, ERPGs, TEELs, and IDLH).
List of data sources.
| Molecular Formula: |
|
Flash Point:
200.0 ° F
(EPA, 1998)
Lower Explosive Limit:
1.8 %
(EPA, 1998)
Upper Explosive Limit: data unavailable
Autoignition Temperature:
230.0 ° F
(USCG, 1999)
Melting Point:
-202.0 ° F
(EPA, 1998)
Vapor Pressure:
0.2 mm Hg
at 68.0 ° F
(EPA, 1998)
Vapor Density:
8.6
(EPA, 1998)
Specific Gravity:
1.653
at 68.0 ° F
(EPA, 1998)
Boiling Point:
392.0 ° F
at 760 mm Hg
Decomposes between 230 - 392° F.
(EPA, 1998)
Molecular Weight:
323.45
(EPA, 1998)
Water Solubility:
<1 mg/mL
at 70° F
(NTP, 1992)
AEGL:
data unavailable
ERPG:
data unavailable
| TEEL-1 | TEEL-2 | TEEL-3 |
|---|---|---|
| 0.468 mg/m3 | 0.781 mg/m3 | 62.4 mg/m3 |
| (SCAPA, 2008) | ||
IDLH:
40.0 mg/m3
(as Pb)
(NIOSH, 2003)
Regulatory Information
Regulatory Names - Names under which this chemical is regulated under several U.S. federal laws: CAA (Clean Air Act of 1990), CERCLA (Comprehensive Environmental Response, Compensation, and Liability Act of 1980, also known as Superfund), EPCRA (Emergency Planning and Community Right-to-Know Act, also known as SARA Title III), and RCRA (Resource Conservation and Recovery Act of 1976).
CAA RMP - Indicates whether this chemical is regulated under Section 112(r) of the Clean Air Act, which lists about 100 toxic, flammable, or explosive hazardous substances. (Section 112(r) mandates the Risk Management Plan regulations.) For listed chemicals, the Threshold Quantity (from 40 CFR 68) is also shown. Facilities that use more than the threshold quantity of a listed chemical in a process are subject to the CAA accidental release prevention provisions.
CERCLA - Indicates whether this chemical is listed as a hazardous substance under CERCLA. For listed chemicals, the Reportable Quantity (from 40 CFR 302) is also shown. Facilities that spill more than the reportable quantity of a listed chemical must report it to federal, state, and local governments.
EHS (EPCRA 302) - Indicates whether this chemical is listed as an Extremely Hazardous Substance under Section 302 of EPCRA. For listed chemicals, the Threshold Planning Quantity (from 40 CFR 355) is also shown. Facilities that store more than the threshold quantity of an EHS chemical must meet the reporting, community right-to-know, and emergency planning requirements of EPCRA.
TRI (EPCRA 313) - Indicates whether this chemical is listed as a toxic chemical under Section 313 (Toxics Release Inventory) of EPCRA. Facilities that manufacture, store, or use significant amounts of Section 313 chemicals may be required to submit annual reports about any releases into the environment (see 40 CFR 372).
RCRA Chemical Code - 4-character identification code assigned to this substance under RCRA.
CAA RMP - Indicates whether this chemical is regulated under Section 112(r) of the Clean Air Act, which lists about 100 toxic, flammable, or explosive hazardous substances. (Section 112(r) mandates the Risk Management Plan regulations.) For listed chemicals, the Threshold Quantity (from 40 CFR 68) is also shown. Facilities that use more than the threshold quantity of a listed chemical in a process are subject to the CAA accidental release prevention provisions.
CERCLA - Indicates whether this chemical is listed as a hazardous substance under CERCLA. For listed chemicals, the Reportable Quantity (from 40 CFR 302) is also shown. Facilities that spill more than the reportable quantity of a listed chemical must report it to federal, state, and local governments.
EHS (EPCRA 302) - Indicates whether this chemical is listed as an Extremely Hazardous Substance under Section 302 of EPCRA. For listed chemicals, the Threshold Planning Quantity (from 40 CFR 355) is also shown. Facilities that store more than the threshold quantity of an EHS chemical must meet the reporting, community right-to-know, and emergency planning requirements of EPCRA.
TRI (EPCRA 313) - Indicates whether this chemical is listed as a toxic chemical under Section 313 (Toxics Release Inventory) of EPCRA. Facilities that manufacture, store, or use significant amounts of Section 313 chemicals may be required to submit annual reports about any releases into the environment (see 40 CFR 372).
RCRA Chemical Code - 4-character identification code assigned to this substance under RCRA.
| Regulatory Names: |
|
CAA RMP:
Not a regulated chemical.
CERCLA:
Regulated chemical with a Reportable Quantity of 10 pounds.
EHS (EPCRA 302):
Regulated chemical with a
Reportable Quantity of 10 pounds and a
Threshold Planning Quantity of 100 pounds.
TRI (EPCRA 313):
Not a regulated chemical.
RCRA Chemical Code:
P110
Alternate Chemical Names
This section provides a listing of alternate names for this chemical, including trade names, synonyms, and foreign names.
- LEAD TETRAETHYL
- LEAD, TETRAETHYL-
- MOTOR FUEL ANTIKNOCK COMPOUNDS (CONTAIN LEAD) {TETRAETHYL LEAD}
- NCI-C54988
- PLOMB TÉTRAÉTHYLE, LIQUIDE (DOT FRENCH)
- PLUMBANE, TETRAETHYL
- PLUMBANE, TETRAETHYL-
- TEL
- TETRAETHYL LEAD
- TETRAETHYL LEAD (AS PB)
- TETRAETHYL LEAD, [LIQUID]
- TETRAETHYL PLUMBANE
- TETRAETHYLLEAD
- TETRAETHYLPLUMBANE
- TETRAETILO DE PLOMO, LÍQUIDO (DOT SPANISH)