Add to MyChemicals Print Friendly Page
Chemical Datasheet

ARSINE

2.3 - Poisonous gas 2.1 - Flammable gas
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 7784-42-1   (ARSINE)
  • Poison Gas
  • Flammable Gas
none
NIOSH Pocket Guide International Chem Safety Card
Arsineexternal_link
NFPA 704
Diamond Hazard Value Description
4
4 2
Blue Health 4 Can be lethal.
Red Flammability 4 Burns readily. Rapidly or completely vaporizes at atmospheric pressure and normal ambient temperature.
Yellow Instability 2 Readily undergoes violent chemical changes at elevated temperatures and pressures.
White Special
(NFPA, 2010)
General Description
A colorless gas with a disagreeable garlic odor. Flammable. Heavier than air. Flame easily flashes back to the source of leak. Extremely toxic by inhalation; has been used as a military poison gas. Confirmed human carcinogen. Under prolonged exposure to fire or heat containers may rupture violently and rocket.

Rate of onset: Immediate to 24 hours

Persistence: Minutes to hours

Odor threshold: 0.5 ppm

Source/use/other hazard: Used in electronics industry; reacts with H20 (don't use H2O in fire).

Hazards

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
Air & Water Reactions
Highly flammable. On exposure to light, decomposes rapidly depositing shiny black arsenic.
Fire Hazard
Vapors may travel to a source of ignition and flash back. Container may explode in heat of fire. When heated to decomposition, emits highly toxic fumes. Can react vigorously with oxidizing materials. May explode when exposed to chlorine, nitric acid, or potassium plus ammonia. On exposure to light, moist arsine decomposes quickly, depositing shiny black arsenic. (EPA, 1998)
Health Hazard
This material is highly toxic by inhalation; a very short exposure to small quantities may cause death or permanent injury. Arsine is the most powerful hemolytic poison encountered in industry. (EPA, 1998)
Reactivity Profile
ARSINE decomposes into its elements (arsenic, gaseous hydrogen) when heated to 300°C. Can form accidentally by the reaction of arsenic impurities with mineral acids (hydrochloric acid, sulfuric acid) in the presence of common metals (iron, zinc). A reducing agent---not oxidized by air at room temperature [Kirk-Othmer, 3rd ed., Vol. 3, 1978, p. 251], but may react vigorously with other oxidizing agents [Sax, 9th ed., 1996, p. 279]. Moderately explosive in combination with chlorine or nitric acid. When heated to decomposition or ignited, it emits highly toxic fumes of metallic arsenic.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

Response Recommendations

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 119 [Gases - Toxic - Flammable]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.

SPILL: If this material is being used as a weapon, see ERG Table 1 - Initial Isolation and Protective Action Distances on the ERG Guide 119 datasheet for unassigned UN/NA numbers. Otherwise see ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 2188 datasheet.

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions. (ERG, 2020)
Firefighting
Cool containers that are exposed to flames with water from the side until well after fire is out. Isolate for 1/2 mile in all directions if tank car or truck is involved in fire.

Let small fires burn. Use water spray, fog, or foam for large fires. For massive fire in cargo area use unmanned hose holder or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (EPA, 1998)
Non-Fire Response
Excerpt from ERG Guide 119 [Gases - Toxic - Flammable]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Do not direct water at spill or source of leak. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. FOR CHLOROSILANES, use AFFF alcohol-resistant medium-expansion foam to reduce vapors. If possible, turn leaking containers so that gas escapes rather than liquid. Prevent entry into waterways, sewers, basements or confined areas. Isolate area until gas has dispersed. (ERG, 2020)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Arsineexternal link:

Skin: FROSTBITE - Compressed gases may create low temperatures when they expand rapidly. Leaks and uses that allow rapid expansion may cause a frostbite hazard. Wear appropriate personal protective clothing to prevent the skin from becoming frozen.

Eyes: FROSTBITE - Wear appropriate eye protection to prevent eye contact with the liquid that could result in burns or tissue damage from frostbite.

Wash skin: No recommendation is made specifying the need for washing the substance from the skin (either immediately or at the end of the work shift).

Remove: WHEN WET (FLAMMABLE) - Work clothing that becomes wet should be immediately removed due to its flammability hazard (i.e., for liquids with a flash point <100°F).

Change: No recommendation is made specifying the need for the worker to change clothing after the workshift.

Provide: FROSTBITE WASH - Quick drench facilities and/or eyewash fountains should be provided within the immediate work area for emergency use where there is any possibility of exposure to liquids that are extremely cold or rapidly evaporating. (NIOSH, 2023)
DuPont Tychem® Suit Fabrics
Tychem® Fabric Legend
QS = Tychem 2000 SFR
QC = Tychem 2000
SL = Tychem 4000
C3 = Tychem 5000
TF = Tychem 6000
TP = Tychem 6000 FR
RC = Tychem RESPONDER® CSM
TK = Tychem 10000
RF = Tychem 10000 FR
Testing Details
The fabric permeation data was generated for DuPont by a third party laboratory. Permeation data for industrial chemicals is obtained per ASTM F739. Normalized breakthrough times (the time at which the permeation rate exceeds 0.1 μg/cm2/min) are reported in minutes. All chemicals have been tested between approximately 20°C and 27°C unless otherwise stated. All chemicals have been tested at a concentration of greater than 95% unless otherwise stated.
Chemical warfare agents (Lewisite, Sarin, Soman, Sulfur Mustard, Tabun and VX Nerve Agent) have been tested at 22°C and 50% relative humidity per military standard MIL-STD-282. "Breakthrough time" for chemical warfare agents is defined as the time when the cumulative mass which permeated through the fabric exceeds the limit in MIL-STD-282 [either 1.25 or 4.0 μg/cm2].
A Caution from DuPont
This information is based upon technical data that DuPont believes to be reliable on the date issued. It is subject to revision as additional knowledge and experience are gained. The information reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. If fabric becomes torn,abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, DuPont makes no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent, trademark or technical information of DuPont or others covering any material or its use.
Normalized Breakthrough Times (in Minutes)
Chemical CAS Number State QS QC SL C3 TF TP RC TK RF
Arsine 7784-42-1 Vapor >480 >480 >480
> indicates greater than.

Special Warning from DuPont: Tychem® and Tyvek® fabrics should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Only...

...Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments are designed and tested to help reduce burn injury during escape from a flash fire. Users of Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments should not knowingly enter an explosive environment. Tychem® garments with attached socks must be worn inside protective outer footwear and are not suitable as outer footwear. These attached socks do not have adequate durability or slip resistance to be worn as the outer foot covering.

(DuPont, 2023)

First Aid
Warning: Effects usually appear within 30 to 60 minutes, but may be delayed for several hours. Caution is advised.

Note: Arsine is the most powerful hemolytic poison encountered in industry.

Signs and Symptoms of Acute Arsine Exposure: Acute arsine exposure may be fatal. Headache and a garlicky odor of the breath may be the first signs and symptoms noted following acute exposure to arsine. Victims may experience hypotension (low blood pressure), generalized weakness, and muscle cramping. Gastrointestinal effects include nausea, vomiting, anorexia, and abdominal pain. Urine may be colored red or green, and the volume may be reduced. Arsine is corrosive to the skin, eyes, and mucous membranes. Severe exposure may result in cardiac abnormalities.

Emergency Life-Support Procedures: Acute exposure to arsine may require decontamination and life support for the victims. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Victims must be transported to a health care facility as quickly as possible. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.

Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to arsine.
2. RUSH to a health care facility!
3. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
4. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.

Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to arsine.
2. RUSH to a health care facility!
3. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
4. Remove contaminated clothing as soon as possible.
5. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
6. THOROUGHLY wash exposed skin areas with water.
7. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.

Ingestion Exposure: No information is available. (EPA, 1998)

Physical Properties

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • AsH3
Flash Point: data unavailable
Lower Explosive Limit (LEL): Extremely flammable; may be ignited by heat, sparks, or flames. (EPA, 1998)
Upper Explosive Limit (UEL): Extremely flammable; may be ignited by heat, sparks, or flames. (EPA, 1998)
Autoignition Temperature: data unavailable
Melting Point: -179°F (EPA, 1998)
Vapor Pressure: greater than 1 atm (EPA, 1998)
Vapor Density (Relative to Air): 2.66 to 2.695 (EPA, 1998)
Specific Gravity: 1.689 at 185°F (EPA, 1998) - Denser than water; will sink
Boiling Point: -80.4°F at 760 mmHg (EPA, 1998)
Molecular Weight: 77.93 (EPA, 1998)
Water Solubility: 20 cc/100 cc (NTP, 1992)
Ionization Energy/Potential: 9.89 eV (NIOSH, 2023)
IDLH: 3 ppm ; A potential occupational carcinogen. (NIOSH, 2023)

AEGLs (Acute Exposure Guideline Levels)

Final AEGLs for Arsine (7784-42-1)
Exposure Period AEGL-1 AEGL-2 AEGL-3
10 minutes NR 0.3 ppm 0.91 ppm
30 minutes NR 0.21 ppm 0.63 ppm
60 minutes NR 0.17 ppm 0.5 ppm
4 hours NR 0.04 ppm 0.13 ppm
8 hours NR 0.02 ppm 0.06 ppm
NR = Not Recommended since AEGL-2 concentrations are below sensory effect concentrations.
(NAC/NRC, 2023)

ERPGs (Emergency Response Planning Guidelines)

Chemical ERPG-1 ERPG-2 ERPG-3
Arsine (7784-42-1) NA 0.5 ppm 1.5 ppm
NA = not appropriate.
(AIHA, 2022)

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Arsine (7784-42-1) 0.015 ppm 0.17 ppm 0.5 ppm
(DOE, 2018)

Regulatory Information

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Arsenic Compounds N020 & 313
Arsine 7784-42-1 100 pounds 100 pounds 1000 pounds

(EPA List of Lists, 2022)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

RELEASE THEFT SABOTAGE
Chemical of Interest CAS Number Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Arsine 7784-42-1 1.00 % 1000 pounds toxic 0.67 % 15 pounds WME

(CISA, 2007)

OSHA Process Safety Management (PSM) Standard List

Chemical Name CAS Number Threshold Quantity (TQ)
Arsine (also called Arsenic Hydride) 7784-42-1 100 pounds

(OSHA, 2019)

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.