Chemical Datasheet
COAL TAR OIL, [LIGHT DISTILLATE] |
|
|||||||||
Chemical Identifiers
UN/NA Number - The United Nations-North America number (also called UN number or DOT number). 4-digit number identifying an individual chemical or group of chemicals with similar characteristics. Required on shipping papers; often shown on placards or labels. This numbering system was developed by the U.S. Department of Transportation, and then became the UN standard system for classifying hazardous materials.
CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.
CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.
DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.
NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and reactivity hazards, along with special hazards such as water- and air-reactivity. (The NFPA 704 diamond is also shown at the top of the datasheet.) See a guide to the NFPA diamond.
General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.
List of data sources.
CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.
CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.
DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.
NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and reactivity hazards, along with special hazards such as water- and air-reactivity. (The NFPA 704 diamond is also shown at the top of the datasheet.) See a guide to the NFPA diamond.
General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.
List of data sources.
| UN/NA Number | CAS Number | CHRIS Code | DOT Hazard Label |
|---|---|---|---|
|
|
| NFPA 704: |
|
General Description
Low-boiling liquid separated from coal tar by distillation. Contains benzene, toluene, xylenes, cumenes, coumarone and indene, among other substances. Colorless to yellow with a pleasant odor. Floats on water. Irritating vapor . Flash point is typically below 80° F
Hazards
Reactivity Alerts - Special alerts if the chemical is especially reactive
(see list of reactivity alerts).
Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.
Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).
Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).
Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).
Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.
List of data sources.
Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.
Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).
Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).
Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).
Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.
List of data sources.
Reactivity Alerts
- Highly Flammable
Air & Water Reactions
Highly flammable.
Fire Hazard
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water. Substance may be transported hot. If molten aluminum is involved, refer to GUIDE 169 below.
GUIDE 169: Substance is transported in molten form at a temperature above 705° C (1300° F). Violent reaction with water; contact may cause an explosion or may produce a flammable gas. Will ignite combustible materials (wood, paper, oil, debris, etc.). Contact with nitrates or other oxidizers may cause an explosion. Contact with containers or other materials, including cold, wet or dirty tools, may cause an explosion. Contact with concrete will cause spalling and small pops. (ERG, 2008)
GUIDE 169: Substance is transported in molten form at a temperature above 705° C (1300° F). Violent reaction with water; contact may cause an explosion or may produce a flammable gas. Will ignite combustible materials (wood, paper, oil, debris, etc.). Contact with nitrates or other oxidizers may cause an explosion. Contact with containers or other materials, including cold, wet or dirty tools, may cause an explosion. Contact with concrete will cause spalling and small pops. (ERG, 2008)
Health Hazard
Vapor causes slight irritation of nose and throat, smarting of eyes. Liquid may irritate skin on prolonged contact. (USCG, 1999)
Reactivity Profile
COAL TAR OIL contains phenols, which react as weak organic acids and are incompatible with strong reducing substances such as hydrides, nitrides, alkali metals, and sulfides. Flammable gas (H2) is often generated, and the heat of the reaction may ignite the gas. Phenols also generate heat with bases. Such heating may initiate polymerization. Phenols are exothermically sulfonated very readily (for example, by concentrated sulfuric acid at room temperature) and are also nitrated very rapidly, even by dilute nitric acid. Nitrated phenols can explode when heated and form metal salts that may detonate when shocked.
Belongs to the Following Reactive Group(s)
Response Recommendations
Firefighting - Response recommendations if the chemical is on fire (or near a fire).
Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).
Protective Clothing - Recommendations for protective gear and, in some cases, a table of breakthrough times for protective materials.
First Aid - Recommended first aid treatment for people exposed to the chemical.
List of data sources.
Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).
Protective Clothing - Recommendations for protective gear and, in some cases, a table of breakthrough times for protective materials.
First Aid - Recommended first aid treatment for people exposed to the chemical.
List of data sources.
Firefighting
Fire Extinguishing Agents Not to Be Used: Water may be ineffective.Fire Extinguishing Agents: Dry chemical, foam, or carbon dioxide (USCG, 1999)
Non-Fire Response
Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers. Build dikes to contain flow as necessary. Attempt to stop leak if without undue personnel hazard. Use water spray to knock-down vapors. Land spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid material. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Absorb bulk liquid with fly ash, cement powder, or commercial sorbents. Water spill: Use natural barriers or oil spill control booms to limit spill travel. Remove trapped material with suction hoses.
Protective Clothing
Protective gloves; goggles or face shield. (USCG, 1999)
First Aid
INGESTION: have victim drink water or milk; do NOT induce vomiting.
EYES: flush with water for at least 15 min.
SKIN: wipe off and wash with soap and water. (USCG, 1999)
EYES: flush with water for at least 15 min.
SKIN: wipe off and wash with soap and water. (USCG, 1999)
Physical Properties
This section contains physical properties, flammability limits, and toxic thresholds for this chemical (see
definitions of each property).
More property data is available for common chemicals.
Guide to toxic levels of concern (AEGLs, ERPGs, TEELs, and IDLH).
List of data sources.
Guide to toxic levels of concern (AEGLs, ERPGs, TEELs, and IDLH).
List of data sources.
Molecular Formula:
data unavailable
Flash Point:
60-77 ° F
(USCG, 1999)
Lower Explosive Limit:
1.3 %
(USCG, 1999)
Upper Explosive Limit:
8.0 %
(USCG, 1999)
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density: data unavailable
Specific Gravity:
0.9
at 68.0 ° F
(est.)
(USCG, 1999)
Boiling Point:
223 to 333 ° F
at 760.0 mm Hg
(USCG, 1999)
Molecular Weight: data unavailable
Water Solubility: data unavailable
AEGL:
data unavailable
ERPG:
data unavailable
TEEL:
data unavailable
IDLH: data unavailable
Regulatory Information
Regulatory Names - Names under which this chemical is regulated under several U.S. federal laws: CAA (Clean Air Act of 1990), CERCLA (Comprehensive Environmental Response, Compensation, and Liability Act of 1980, also known as Superfund), EPCRA (Emergency Planning and Community Right-to-Know Act, also known as SARA Title III), and RCRA (Resource Conservation and Recovery Act of 1976).
CAA RMP - Indicates whether this chemical is regulated under Section 112(r) of the Clean Air Act, which lists about 100 toxic, flammable, or explosive hazardous substances. (Section 112(r) mandates the Risk Management Plan regulations.) For listed chemicals, the Threshold Quantity (from 40 CFR 68) is also shown. Facilities that use more than the threshold quantity of a listed chemical in a process are subject to the CAA accidental release prevention provisions.
CERCLA - Indicates whether this chemical is listed as a hazardous substance under CERCLA. For listed chemicals, the Reportable Quantity (from 40 CFR 302) is also shown. Facilities that spill more than the reportable quantity of a listed chemical must report it to federal, state, and local governments.
EHS (EPCRA 302) - Indicates whether this chemical is listed as an Extremely Hazardous Substance under Section 302 of EPCRA. For listed chemicals, the Threshold Planning Quantity (from 40 CFR 355) is also shown. Facilities that store more than the threshold quantity of an EHS chemical must meet the reporting, community right-to-know, and emergency planning requirements of EPCRA.
TRI (EPCRA 313) - Indicates whether this chemical is listed as a toxic chemical under Section 313 (Toxics Release Inventory) of EPCRA. Facilities that manufacture, store, or use significant amounts of Section 313 chemicals may be required to submit annual reports about any releases into the environment (see 40 CFR 372).
RCRA Chemical Code - 4-character identification code assigned to this substance under RCRA.
CAA RMP - Indicates whether this chemical is regulated under Section 112(r) of the Clean Air Act, which lists about 100 toxic, flammable, or explosive hazardous substances. (Section 112(r) mandates the Risk Management Plan regulations.) For listed chemicals, the Threshold Quantity (from 40 CFR 68) is also shown. Facilities that use more than the threshold quantity of a listed chemical in a process are subject to the CAA accidental release prevention provisions.
CERCLA - Indicates whether this chemical is listed as a hazardous substance under CERCLA. For listed chemicals, the Reportable Quantity (from 40 CFR 302) is also shown. Facilities that spill more than the reportable quantity of a listed chemical must report it to federal, state, and local governments.
EHS (EPCRA 302) - Indicates whether this chemical is listed as an Extremely Hazardous Substance under Section 302 of EPCRA. For listed chemicals, the Threshold Planning Quantity (from 40 CFR 355) is also shown. Facilities that store more than the threshold quantity of an EHS chemical must meet the reporting, community right-to-know, and emergency planning requirements of EPCRA.
TRI (EPCRA 313) - Indicates whether this chemical is listed as a toxic chemical under Section 313 (Toxics Release Inventory) of EPCRA. Facilities that manufacture, store, or use significant amounts of Section 313 chemicals may be required to submit annual reports about any releases into the environment (see 40 CFR 372).
RCRA Chemical Code - 4-character identification code assigned to this substance under RCRA.
Regulatory Names:
none
CAA RMP:
Not a regulated chemical.
CERCLA:
Not a regulated chemical.
EHS (EPCRA 302):
Not a regulated chemical.
TRI (EPCRA 313):
Not a regulated chemical.
RCRA Chemical Code:
none
Alternate Chemical Names
This section provides a listing of alternate names for this chemical, including trade names, synonyms, and foreign names.
- COAL TAR OIL, [FLAMMABLE LIQUID]
- LIGHT OIL
- OILS, MISCELLANEOUS: COAL TAR