Print
Chemical Datasheet

2-METHYL-1-PENTENE

3 - Flammable liquid

Chemical Identifiers

CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 763-29-1   (2-METHYL-1-PENTENE)
  • 3295
  • Flammable Liquid
  • MPE
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
Diamond Hazard Value Description
3
1 0
Blue Health 1 Can cause significant irritation.
Red Flammability 3 Can be ignited under almost all ambient temperature conditions.
Yellow Instability 0 Normally stable, even under fire conditions.
White Special
(NFPA, 2010)
General Description
Colorless liquid. Flash point -15°F. Floats on water. Irritating vapor.

Hazards

Reactivity Alerts
Air & Water Reactions
Highly flammable. Insoluble in water.
Fire Hazard
Behavior in Fire: Can react vigorously with oxidizing materials. (USCG, 1999)
Health Hazard
INHALATION: May produce anesthetic effects. EYES: Moderate eye irritation possible. (USCG, 1999)
Reactivity Profile
2-METHYL-1-PENTENE may react vigorously with strong oxidizing agents. May react exothermically with reducing agents to release hydrogen gas. In the presence of various catalysts (such as acids) or initiators, may undergo exothermic addition polymerization reactions.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below.

Response Recommendations

Isolation and Evacuation
Excerpt from 128 Polymerizable warning [Flammable Liquids (Water-Immiscible)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Fire Extinguishing Agents Not to Be Used: Water may be ineffective.

Fire Extinguishing Agents: Foam, carbon dioxide, dry chemical. (USCG, 1999)
Non-Fire Response
Excerpt from 128 Polymerizable warning [Flammable Liquids (Water-Immiscible)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2020)
Protective Clothing
Rubber or neoprene gloves, splash goggles and NIOSH approved self-contained breathing apparatus. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Call a doctor.

INHALATION: Remove from contaminated atmosphere. If respiration is labored, administer oxygen. If unconscious, administer artificial respiration.

EYES: Flush with clear tap water for 15 min.

SKIN: Wash with soap and water.

INGESTION: Do not induce vomiting. Physician may remove by cuffed tube lavage. (USCG, 1999)

Physical Properties

Chemical Formula:
  • C6H12
Flash Point: -15°F (est.) (USCG, 1999)
Lower Explosive Limit (LEL): 1.2 % (USCG, 1999)
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: 572°F (USCG, 1999)
Melting Point: -212.3°F (USCG, 1999)
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 0.685 at 59°F (USCG, 1999) - Less dense than water; will float
Boiling Point: 143.8°F at 760 mmHg (USCG, 1999)
Molecular Weight: 84.156 (USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

No PAC information available.

Regulatory Information

EPA Consolidated List of Lists

No regulatory information available.

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names