Print
Chemical Datasheet
BERYLLIUM OXIDE |
|
Chemical Identifiers
CAS Number |
UN/NA Number |
DOT Hazard Label |
USCG CHRIS Code |
|
|
|
|
NIOSH Pocket Guide |
International Chem Safety Card |
Beryllium & beryllium compounds (as Be)
|
|
NFPA 704
data unavailable
General Description
Odorless white solid. Sinks in water. (USCG, 1999)
Hazards
Reactivity Alerts
Air & Water Reactions
The amount of heat generated by hydrolysis may be large.
Fire Hazard
Special Hazards of Combustion Products: Toxic beryllium oxide fume may form in fire. (USCG, 1999)
Health Hazard
Any dramatic, unexplained weight loss should be considered as possible first indication of beryllium disease. Other symptoms include anorexia, fatigue, weakness, malaise. Inhalation causes pneumonitis, nasopharyngitis, tracheobronchitis, dyspnea, chronic cough. Contact with dust causes conjunctival inflammation of eyes and irritation of skin. (USCG, 1999)
Reactivity Profile
No information available.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents
Use caution: Liquids with this reactive group classification have been
known to react with the
absorbents
listed below.
- Cellulose-Based Absorbents
- Mineral-Based & Clay-Based Absorbents
Response Recommendations
Isolation and Evacuation
Excerpt from 154
[Substances - Toxic and/or Corrosive (Non-Combustible)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.
FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Excerpt from 154
[Substances - Toxic and/or Corrosive (Non-Combustible)]:
SMALL FIRE: Dry chemical, CO2 or water spray.
LARGE FIRE: Dry chemical, CO2, alcohol-resistant foam or water spray. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal.
FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2020)
Non-Fire Response
Excerpt from 154
[Substances - Toxic and/or Corrosive (Non-Combustible)]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2020)
Protective Clothing
Respiratory protection; gloves; freshly laundered clothing; chemical safety goggles (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
INHALATION: take chest x-ray immediately to check for pneumonitis.
INGESTION: induce vomiting; get medical attention.
EYES: flush with water for at least 15 min.; get medical attention.
SKIN: cuts or puncture wounds in which beryllium may be embedded under the skin should be thoroughly cleansed immediately by a physician. (USCG, 1999)
Physical Properties
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity:
3
at 68°F
(USCG, 1999)
- Denser than water; will sink
Boiling Point: data unavailable
Molecular Weight:
25
(USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH:
4 mg Be/m3
; A potential occupational carcinogen.
(NIOSH, 2023)
AEGLs (Acute Exposure Guideline Levels)
No AEGL information available.
ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.
PACs (Protective Action Criteria)
Chemical |
PAC-1 |
PAC-2 |
PAC-3 |
Beryllium oxide (1304-56-9)
|
0.0063 mg/m3 |
0.069 mg/m3 |
0.28 mg/m3 |
(DOE, 2018)
Regulatory Information
EPA Consolidated List of Lists
Regulatory Name |
CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ |
EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
Beryllium Compounds |
N050 |
|
|
& |
313 |
|
|
(EPA List of Lists, 2022)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
No regulatory information available.
OSHA Process Safety Management (PSM) Standard List
No regulatory information available.
Alternate Chemical Names
- BERYLLIA
- BERYLLIUM OXIDE
- BROMELITE