Print
Chemical Datasheet
DIMETHYL ETHER |
|
Chemical Identifiers
CAS Number |
UN/NA Number |
DOT Hazard Label |
USCG CHRIS Code |
- 115-10-6
|
|
|
|
NIOSH Pocket Guide |
International Chem Safety Card |
none
|
|
NFPA 704
General Description
Dimethyl ether is a colorless gas with a faint ethereal odor. It is shipped as a liquefied gas under its vapor pressure. Contact with the liquid can cause frostbite. It is easily ignited. Its vapors are heavier than air. Any leak can be either liquid or vapor. It can asphyxiate by the displacement of air. Under prolonged exposure to fire or intense heat the containers may rupture violently and rocket.
Hazards
Reactivity Alerts
- Highly Flammable
- Peroxidizable Compound
Air & Water Reactions
Highly flammable. Upon standing and exposure to air (oxygen) tendency to form explosive peroxides. When ethers containing peroxides are heated (distilled) they can detonate [Lewis, 3rd ed., 1993, p. 854].
Fire Hazard
Behavior in Fire: Containers may explode. Vapors are heavier than air and may travel long distance to a source of ignition and flash back. (USCG, 1999)
Health Hazard
Inhalation produces some anesthesia (but less than that of ethyl ether), blurring of vision, headache, intoxication, loss of consciousness. Liquid or concentrated vapor irritates eyes. Contact of liquid with skin may cause frostbite. (USCG, 1999)
Reactivity Profile
DIMETHYL ETHER is a colorless, highly flammable gas (b. p. -24°C), slightly toxic. Very dangerous fire and explosion hazard when exposed to flame, sparks, heat or strong oxidizers. Violent reaction with aluminum hydride, lithium aluminum hydride. Upon standing and exposure to air (oxygen) tendency to form explosive peroxides. When ethers containing peroxides are heated (distilled) they can detonate [Lewis, 3rd ed., 1993, p. 854].
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents
No information available.
Response Recommendations
Isolation and Evacuation
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.
LARGE SPILL: Consider initial downwind evacuation for at least 800 meters (1/2 mile).
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions. In fires involving Liquefied Petroleum Gases (LPG) (UN1075), Butane (UN1011), Butylene (UN1012), Isobutylene (UN1055), Propylene (UN1077), Isobutane (UN1969), and Propane (UN1978), also refer to the "BLEVE - Safety Precautions" section. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:
DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED. CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966) and Hydrogen and Methane mixture, compressed (UN2034) will burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.).
SMALL FIRE: Dry chemical or CO2.
LARGE FIRE: Water spray or fog. If it can be done safely, move undamaged containers away from the area around the fire. CAUTION: For LNG - Liquefied natural gas (UN1972) pool fires, DO NOT USE water. Use dry chemical or high-expansion foam.
FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. If possible, turn leaking containers so that gas escapes rather than liquid. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Do not direct water at spill or source of leak. CAUTION: For LNG - Liquefied natural gas (UN1972), DO NOT apply water, regular or alcohol-resistant foam directly on spill. Use a high-expansion foam if available to reduce vapors. Prevent spreading of vapors through sewers, ventilation systems and confined areas. Isolate area until gas has dispersed. CAUTION: When in contact with refrigerated/cryogenic liquids, many materials become brittle and are likely to break without warning. (ERG, 2024)
Protective Clothing
Mask for organic vapors; plastic or rubber gloves; safety glasses. (USCG, 1999)
DuPont Tychem® Suit Fabrics
Normalized Breakthrough Times (in Minutes)
Chemical |
CAS Number |
State |
QS |
QC |
SL |
C3 |
TF |
TP |
RC |
TK |
RF |
Dimethyl ether |
115-10-6 |
Vapor |
|
|
|
|
|
|
|
>480 |
|
Special Warning from DuPont: Tychem® and Tyvek® fabrics should not be
used around heat, flames, sparks or in potentially flammable or
explosive environments. Only...
(DuPont, 2024)
First Aid
EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.
SKIN: CAUTION: Exposure of skin to compressed gases may result in freezing of the skin. Treatment for frostbite may be necessary. Remove the victim from the source of contamination. IMMEDIATELY wash affected areas gently with COLD water (and soap, if necessary) while removing and isolating all contaminated clothing. Dry carefully with clean, soft towels. If symptoms such as inflammation or irritation develop, IMMEDIATELY call a physician or go to a hospital for treatment.
INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. If symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the victim to a hospital. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater than or equal to that advised under Protective Clothing.
INGESTION: This compound is a gas, therefore inhalation is the first route of exposure. (NTP, 1992)
Physical Properties
Flash Point:
25°F
(NTP, 1992)
Lower Explosive Limit (LEL):
2 %
(USCG, 1999)
Upper Explosive Limit (UEL):
50 %
(USCG, 1999)
Autoignition Temperature:
662°F
(USCG, 1999)
Melting Point:
-217.3°F
(NTP, 1992)
Vapor Pressure:
2.128 mmHg
(NTP, 1992)
Vapor Density (Relative to Air):
1.617
(NTP, 1992)
- Heavier than air; will sink
Specific Gravity:
0.724
at -12.46°F
(USCG, 1999)
- Less dense than water; will float
Boiling Point:
-8°F
at 760 mmHg
(NTP, 1992)
Molecular Weight:
46.07
(NTP, 1992)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable
AEGLs (Acute Exposure Guideline Levels)
No AEGL information available.
ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.
PACs (Protective Action Criteria)
Chemical |
PAC-1 |
PAC-2 |
PAC-3 |
|
Methyl ether; (Dimethyl ether) (115-10-6)
|
3000 ppm |
3800 ppm  |
7200 ppm  |
LEL = 34000 ppm |
(DOE, 2024)
Regulatory Information
EPA Consolidated List of Lists
Regulatory Name |
CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ |
EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
Methane, oxybis- |
115-10-6 |
|
|
|
|
|
10000 pounds |
Methyl ether |
115-10-6 |
|
|
|
|
|
10000 pounds |
(EPA List of Lists, 2024)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
|
RELEASE |
THEFT |
SABOTAGE |
Chemical of Interest |
CAS Number |
Min Conc |
STQ |
Security Issue |
Min Conc |
STQ |
Security Issue |
Min Conc |
STQ |
Security Issue |
Methyl ether; [Methane, oxybis-] |
115-10-6 |
1.00 % |
10000 pounds |
flammable |
|
|
|
|
|
|
(CISA, 2007)
OSHA Process Safety Management (PSM) Standard List
No regulatory information available.
Alternate Chemical Names
- DEMEON D
- DIMETHYL ETHER
- DIMETHYL OXIDE
- DME
- DYMEL A
- ETHER, DIMETHYL
- ETHER, METHYL
- METHANE, OXYBIS-
- METHOXY METHANE
- METHOXYMETHANE
- METHYL ETHER
- METHYL OXIDE
- OXYBISMETHANE
- WOOD ETHER