Print
Chemical Datasheet
COPPER ARSENITE |
|
Chemical Identifiers
CAS Number |
UN/NA Number |
DOT Hazard Label |
USCG CHRIS Code |
|
|
|
|
NIOSH Pocket Guide |
International Chem Safety Card |
Arsenic (inorganic compounds, as As)
|
|
NFPA 704
data unavailable
General Description
Copper arsenite is a fine, light-green powder. It is insoluble in water. It is very toxic by ingestion. It is used as an insecticide and fungicide.
Hazards
Reactivity Alerts
none
Air & Water Reactions
Insoluble in water.
Fire Hazard
Special Hazards of Combustion Products: Poisonous, volatile arsenic oxides may be formed in fires. (USCG, 1999)
Health Hazard
Dust irritates eyes. Ingestion causes gastric disturbance, tremors, muscular cramps, and nervous collapse that may cause death. (USCG, 1999)
Reactivity Profile
COPPER ARSENITE, also known as Scheele's green, reacts with acids to release toxic fumes of arsine gas. This substance decomposes upon heating to produce toxic arsenic-containing fumes. (International Chemical Safety Card 1211)
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents
No information available.
Response Recommendations
Isolation and Evacuation
Excerpt from 151
[Substances - Toxic (Non-Combustible)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.
FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Excerpt from 151
[Substances - Toxic (Non-Combustible)]:
SMALL FIRE: Dry chemical, CO2 or water spray.
LARGE FIRE: Water spray, fog or regular foam. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal. Avoid aiming straight or solid streams directly onto the product.
FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2020)
Non-Fire Response
Excerpt from 151
[Substances - Toxic (Non-Combustible)]:
Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Cover with plastic sheet to prevent spreading. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2020)
Protective Clothing
Dust respirator; rubber gloves; goggles or face shield. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Following ingestion or unusually severe exposure to dust, get medical attention. Alert doctor to possibility of arsenic poisoning.
EYES: flush with water for 15 min.
SKIN: wash with soap and water.
INGESTION: give large amounts of water; induce vomiting; give cathartic, such as 2 oz. of Epsom salt in water. (USCG, 1999)
Physical Properties
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity:
greater than 1.1
at 68°F
(est)
(USCG, 1999)
Boiling Point: data unavailable
Molecular Weight:
277.4
(USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH:
5 mg As/m3
; A potential occupational carcinogen.
(NIOSH, 2023)
AEGLs (Acute Exposure Guideline Levels)
No AEGL information available.
ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.
PACs (Protective Action Criteria)
No PAC information available.
Regulatory Information
EPA Consolidated List of Lists
Regulatory Name |
CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ |
EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
Arsenic Compounds |
N020 |
|
|
& |
313 |
|
|
Copper Compounds |
N100 |
|
|
& |
313 |
|
|
(EPA List of Lists, 2022)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
No regulatory information available.
OSHA Process Safety Management (PSM) Standard List
No regulatory information available.
Alternate Chemical Names
- AIR-FLO GREEN
- ARSENIOUS ACID (H3ASO3), COPPER(2+) SALT (1:1)
- COPPER ARSENITE
- COPPER ARSENITE (CUHASO3)
- COPPER ARSENITE, [SOLID]
- COPPER ORTHOARSENITE
- CUPRIC ARSENITE
- CUPRIC GREEN
- SCHEELE'S GREEN
- SWEDISH GREEN