Print
Chemical Datasheet

ALCOHOL C-12 C-16 POLY (1-6) ETHOXYLATE

9 - Miscellaneous hazardous material

Chemical Identifiers

CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 68551-12-2
  • 3082
  • Class 9
none
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
data unavailable
General Description
A colorless liquid with a mild odor. Completely miscible with water. A major threat to the environment in case of a spill. Immediate steps should be taken to limit spread. Can easily penetrate the soil and contaminate ground water and nearby streams. Very toxic to aquatic organisms. Irritating to the eyes and respiratory tract. Prolonged exposure to the skin can cause reddening and scaling. Used in the making of surfactants.

Hazards

Reactivity Alerts
Air & Water Reactions
No rapid reaction with air. No rapid reaction with water.
Fire Hazard
Excerpt from 171 Polymerizable warning [Substances (Low to Moderate Hazard)]:

Some may burn but none ignite readily. Containers may explode when heated. Some may be transported hot. For UN3508, Capacitor, asymmetric, be aware of possible short circuiting as this product is transported in a charged state. Polymeric beads, expandable (UN2211) may evolve flammable vapours. (ERG, 2020)
Health Hazard
Excerpt from 171 Polymerizable warning [Substances (Low to Moderate Hazard)]:

Inhalation of material may be harmful. Contact may cause burns to skin and eyes. Inhalation of Asbestos dust may have a damaging effect on the lungs. Fire may produce irritating, corrosive and/or toxic gases. Some liquids produce vapors that may cause dizziness or asphyxiation. Runoff from fire control or dilution water may cause environmental contamination. (ERG, 2020)
Reactivity Profile
Alcohol C-12 C-16 Poly (1-6) ethoxylate is stable up to 50°C. Oxidizes on exposure to the air to form peroxides and peracids. Combustible but not flammable (flash point > 179°C). Auto-ignition temperature: 230°C. May react with strong oxidizing agents, strong acids, and strong bases. Incompatible with copper and copper alloys and aluminum. A mixture of polyether alcohols of formula R-O-(CH2CH2-O-)n-H where R is a C-12 through C-16 alkyl group and n equals 1 through 6. Synthesized by treating a mixture of C-12 to C-16 alcohols with ethylene oxide.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbent listed below.

Response Recommendations

Isolation and Evacuation
Excerpt from 171 Polymerizable warning [Substances (Low to Moderate Hazard)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Excerpt from 171 Polymerizable warning [Substances (Low to Moderate Hazard)]:

SMALL FIRE: Dry chemical, CO2, water spray or regular foam.

LARGE FIRE: Water spray, fog or regular foam. Do not scatter spilled material with high-pressure water streams. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal.

FIRE INVOLVING TANKS: Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2020)
Non-Fire Response
Excerpt from 171 Polymerizable warning [Substances (Low to Moderate Hazard)]:

Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent dust cloud. For Asbestos, avoid inhalation of dust. Cover spill with plastic sheet or tarp to minimize spreading. Do not clean up or dispose of, except under supervision of a specialist.

SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.

SMALL SPILL: Pick up with sand or other non-combustible absorbent material and place into containers for later disposal.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Cover powder spill with plastic sheet or tarp to minimize spreading. Prevent entry into waterways, sewers, basements or confined areas. (ERG, 2020)
Protective Clothing
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:

Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2020)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Excerpt from 171 Polymerizable warning [Substances (Low to Moderate Hazard)]:

Call 911 or emergency medical service. Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air if it can be done safely. Give artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. (ERG, 2020)

Physical Properties

Chemical Formula: data unavailable
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight: data unavailable
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

No PAC information available.

Regulatory Information

EPA Consolidated List of Lists

No regulatory information available.

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names