Print
Chemical Datasheet
AMMONIA, SOLUTION, WITH MORE THAN 10% BUT NOT MORE THAN 35% AMMONIA |
|
Chemical Identifiers
CAS Number |
UN/NA Number |
DOT Hazard Label |
USCG CHRIS Code |
- 7664-41-7
|
|
|
none
|
NIOSH Pocket Guide |
International Chem Safety Card |
Ammonia
|
|
NFPA 704
General Description
A colorless aqueous liquid solution with a strong odor of ammonia. Both liquid and vapors extremely irritating, especially to the eyes.
Hazards
Reactivity Alerts
none
Air & Water Reactions
Water soluble.
Fire Hazard
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:
Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. Some are oxidizers and may ignite combustibles (wood, paper, oil, clothing, etc.). Corrosives in contact with metals may evolve flammable hydrogen gas. Containers may explode when heated. For electric vehicles or equipment, ERG Guide 147 (lithium ion or sodium ion batteries) or ERG Guide 138 (sodium batteries) should also be consulted. (ERG, 2024)
Health Hazard
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:
TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury or death. Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental contamination. (ERG, 2024)
Reactivity Profile
AMMONIA SOLUTION is basic. Reacts exothermically with acids to produce water and ammonium salts, which, being generally water-soluble, stay in the solution. The heat can cause evolution of quantities of unreacted ammonia as a corrosive, irritating gas. Heating ammonia solutions or treating them with strong bases also causes evolution of gaseous ammonia. Salts with oxidizing acids (such as ammonium chlorate) may explode if obtained in dry or nearly dry form [Kirk-Othmer, 3rd ed., Vol. 2, 1978, p. 470]. Intense sources of ignition can cause air/ammonia mixtures to burn or explode, but the conditions are so specialized that ammonia is generally regarded as nonflammable. Mixing of bleaching powder (hypochlorite solution) with ammonia solutions produces toxic/explosive ammonia trichloride vapors.
Belongs to the Following Reactive Group(s)
- Bases, Weak
- Water and Aqueous Solutions
Potentially Incompatible Absorbents
No information available.
Response Recommendations
Isolation and Evacuation
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:
SMALL FIRE: Dry chemical, CO2 or water spray.
LARGE FIRE: Dry chemical, CO2, alcohol-resistant foam or water spray. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2024)
Protective Clothing
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:
Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
DuPont Tychem® Suit Fabrics
Normalized Breakthrough Times (in Minutes)
Chemical |
CAS Number |
State |
QS |
QC |
SL |
C3 |
TF |
TP |
RC |
TK |
RF |
Ammonia (-33°C, liquid) |
7664-41-7 |
Liquid |
|
|
|
35 |
20 |
30 |
|
>480 |
|
Ammonia (-70°C, liquid) |
7664-41-7 |
Liquid |
|
|
|
>480 |
|
|
|
>480 |
>480 |
Ammonia (gaseous) |
7664-41-7 |
Vapor |
imm |
imm |
26 |
imm |
20 |
90 |
105*/133 |
>480 |
>480 |
Special Warning from DuPont: Tychem® and Tyvek® fabrics should not be
used around heat, flames, sparks or in potentially flammable or
explosive environments. Only...
(DuPont, 2024)
First Aid
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:
Refer to the "General First Aid" section. Specific First Aid: For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required. (ERG, 2024)
Physical Properties
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight: data unavailable
Water Solubility: data unavailable
Ionization Energy/Potential:
10.18 eV
[From NPG: Ammonia]
(NIOSH, 2024)
IDLH:
300 ppm
[From NPG: Ammonia]
(NIOSH, 2024)
AEGLs (Acute Exposure Guideline Levels)
Final AEGLs for Ammonia (7664-41-7)
Exposure Period |
AEGL-1 |
AEGL-2 |
AEGL-3 |
10 minutes |
30 ppm |
220 ppm |
2700 ppm |
30 minutes |
30 ppm |
220 ppm |
1600 ppm |
60 minutes |
30 ppm |
160 ppm |
1100 ppm |
4 hours |
30 ppm |
110 ppm |
550 ppm |
8 hours |
30 ppm |
110 ppm |
390 ppm |
(NAC/NRC, 2024)
ERPGs (Emergency Response Planning Guidelines)
Chemical |
ERPG-1 |
ERPG-2 |
ERPG-3 |
Ammonia (7664-41-7)
|
25 ppm  |
150 ppm |
1500 ppm |
(AIHA, 2022)
PACs (Protective Action Criteria)
Chemical |
PAC-1 |
PAC-2 |
PAC-3 |
|
Ammonia (7664-41-7)
|
30 ppm |
160 ppm |
1100 ppm |
LEL = 150000 ppm |
(DOE, 2024)
Regulatory Information
EPA Consolidated List of Lists
Regulatory Name |
CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ |
EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
Ammonia |
7664-41-7 |
500 pounds |
100 pounds |
100 pounds |
|
|
|
Ammonia (anhydrous) |
7664-41-7 |
500 pounds |
100 pounds |
100 pounds |
X |
|
10000 pounds |
Ammonia (conc 20% or greater) |
7664-41-7 |
|
|
See ammonium hydroxide |
X |
|
20000 pounds |
Ammonia (includes anhydrous ammonia and aqueous ammonia from water dissociable ammonium salts and other sources; 10 percent of total aqueous ammonia is reportable under this listing) |
7664-41-7 |
|
|
|
313 |
|
|
(EPA List of Lists, 2024)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
|
RELEASE |
THEFT |
SABOTAGE |
Chemical of Interest |
CAS Number |
Min Conc |
STQ |
Security Issue |
Min Conc |
STQ |
Security Issue |
Min Conc |
STQ |
Security Issue |
Ammonia (anhydrous) |
7664-41-7 |
1.00 % |
10000 pounds |
toxic |
|
|
|
|
|
|
Ammonia (conc. 20% or greater) |
7664-41-7 |
20.00 % |
20000 pounds |
toxic |
|
|
|
|
|
|
(CISA, 2007)
OSHA Process Safety Management (PSM) Standard List
Chemical Name |
CAS Number |
Threshold Quantity (TQ) |
Ammonia solutions (>44% ammonia by weight) |
7664-41-7 |
15000 pounds |
Ammonia, Anhydrous |
7664-41-7 |
10000 pounds |
(OSHA, 2019)
Alternate Chemical Names
- AMMONIA, SOLUTION, WITH MORE THAN 10% BUT NOT MORE THAN 35% AMMONIA
- AMMONIUM HYDROXIDE, WITH MORE THAN 10% BUT NOT MORE THAN 35% AMMONIA