Print
Chemical Datasheet

PROPYLENE GLYCOL ETHYL ETHER

3 - Flammable liquid

Chemical Identifiers

CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 52125-53-8
  • 3271
  • Flammable Liquid
  • PGY
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
data unavailable
General Description
Colorless liquid. (USCG, 1999)

Hazards

Reactivity Alerts
Air & Water Reactions
Oxidizes readily in air to form unstable peroxides that may explode spontaneously [Bretherick 1979 p.151-154, 164].
Fire Hazard
Special Hazards of Combustion Products: Carbon dioxide and carbon monoxide may be produced in a fire. (USCG, 1999)
Health Hazard
Vapors irritate eyes and nose. (USCG, 1999)
Reactivity Profile
PROPYLENE GLYCOL ETHYL ETHER may react violently with strong oxidizing agents. May generate flammable and/or toxic gases with alkali metals, nitrides, and other strong reducing agents. May initiate the polymerization of isocyanates and epoxides.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbent listed below.

Response Recommendations

Isolation and Evacuation
Excerpt from 127 Polymerizable warning [Flammable Liquids (Water-Miscible)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Fire Extinguishing Agents: Alcohol foam, water spray, dry chemical or carbon dioxide. (USCG, 1999)
Non-Fire Response
Excerpt from 127 Polymerizable warning [Flammable Liquids (Water-Miscible)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2020)
Protective Clothing
Approved respirator; rubber gloves; goggles; clothing to prevent body contact with liquid. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Call for medical aid.

INHALATION: Remove to fresh air.

SKIN OR EYES: Immediately flush with plenty of water. (USCG, 1999)

Physical Properties

Chemical Formula:
  • C5H12O2
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight: 104.15 (USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

No PAC information available.

Regulatory Information

EPA Consolidated List of Lists

No regulatory information available.

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names