Print
Chemical Datasheet
1,1-DICHLORO-1-FLUOROETHANE |
|
Chemical Identifiers
CAS Number |
UN/NA Number |
DOT Hazard Label |
USCG CHRIS Code |
- 1717-00-6
|
none
|
data unavailable
|
none
|
NIOSH Pocket Guide |
International Chem Safety Card |
none
|
- 1,1-DICHLORO-1-FLUOROETHANE
|
NFPA 704
data unavailable
General Description
Colorless liquid at ambient conditions.
Hazards
Reactivity Alerts
none
Air & Water Reactions
No rapid reaction with air. No rapid reaction with water.
Fire Hazard
No information available.
Health Hazard
No information available.
Reactivity Profile
1,1-DICHLORO-1-FLUOROETHANE may be incompatible with strong oxidizing and reducing agents. May be incompatible with some amines, nitrides, azo/diazo compounds, alkali metals, and epoxides. An explosion occurred when an emptied drum of this compound was cut into by a grinder; may be more flammable than once thought.
Belongs to the Following Reactive Group(s)
- Halogenated Organic Compounds
- Fluorinated Organic Compounds
Potentially Incompatible Absorbents
No information available.
Response Recommendations
Isolation and Evacuation
No information available.
Firefighting
No information available.
Non-Fire Response
No information available.
Protective Clothing
No information available.
DuPont Tychem® Suit Fabrics
No information available.
First Aid
No information available.
Physical Properties
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight:
116.95
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH:
1700 ppm
[From IDLH Table: 1,1-Dichloro-1-Fluoroethane (HCFC-141b)]
(NIOSH, 2023)
AEGLs (Acute Exposure Guideline Levels)
Final AEGLs for HCFC 141b (1717-00-6)
Exposure Period |
AEGL-1 |
AEGL-2 |
AEGL-3 |
10 minutes |
1000 ppm |
1700 ppm |
3000 ppm |
30 minutes |
1000 ppm |
1700 ppm |
3000 ppm |
60 minutes |
1000 ppm |
1700 ppm |
3000 ppm |
4 hours |
1000 ppm |
1700 ppm |
3000 ppm |
8 hours |
1000 ppm |
1700 ppm |
3000 ppm |
(NAC/NRC, 2023)
ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.
PACs (Protective Action Criteria)
Chemical |
PAC-1 |
PAC-2 |
PAC-3 |
HCFC-141b; (Dichloro-1-fluoroethane, 1,1-, Freon 141) (1717-00-6)
|
1000 ppm |
1700 ppm |
3000 ppm |
(DOE, 2018)
Regulatory Information
EPA Consolidated List of Lists
Regulatory Name |
CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ |
EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
1,1-Dichloro-1-fluoroethane |
1717-00-6 |
|
|
|
313 |
|
|
HCFC-141b |
1717-00-6 |
|
|
|
X |
|
|
(EPA List of Lists, 2022)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
No regulatory information available.
OSHA Process Safety Management (PSM) Standard List
No regulatory information available.
Alternate Chemical Names
- CFC 141B
- CG 141B
- DAIFLON 141B
- 1,1-DICHLORO-1-FLUOROETHANE
- DICHLOROFLUOROETHANE
- F 141B
- 1-FLUORO-1,1-DICHLOROETHANE
- FORANE 141B
- FRON 141B
- HCFC 141B
- HCFC-141B
- HFA 141B
- ISOTRON 141B
- R 141B
- REFRIGERANT 141B
- SOLKANE 141B