Print
Chemical Datasheet
GLYCERYL TRINITRATE SOLUTION |
|
Chemical Identifiers
CAS Number |
UN/NA Number |
DOT Hazard Label |
USCG CHRIS Code |
|
|
|
none
|
NIOSH Pocket Guide |
International Chem Safety Card |
Nitroglycerine
|
|
NFPA 704
General Description
A colorless solution of glyceryl trinitrate (nitroglycerin) in water. If allowed to dry out, the remaining nitroglycerin is explosive.
Hazards
Reactivity Alerts
- Explosive
- Strong Oxidizing Agent
Air & Water Reactions
No rapid reaction with air. No rapid reaction with water.
Fire Hazard
Excerpt from ERG Guide 113 [Flammable Materials (Wet / Desensitized Explosive)]:
Flammable/combustible material. May be ignited by heat, sparks or flames. DRIED OUT material may explode if exposed to heat, flame, friction or shock; treat as an explosive (ERG Guide 112). Keep material wet with water or treat as an explosive (ERG Guide 112). Runoff to sewer may create fire or explosion hazard. (ERG, 2024)
Health Hazard
Excerpt from ERG Guide 113 [Flammable Materials (Wet / Desensitized Explosive)]:
Some are toxic and may be fatal if inhaled, ingested or absorbed through skin. Specifically, Dinitrophenol, wetted (UN1320); Dinitrophenolates, wetted (UN1321), Sodium dinitro-o-cresolate, wetted (UN1348); and Barium azide, wetted (UN1571) are known to be toxic. Contact may cause burns to skin and eyes. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause environmental contamination. (ERG, 2024)
Reactivity Profile
GLYCERYL TRINITRATE SOLUTION is incompatible with the following: Heat, ozone, shock, acids. Note: An OSHA Class A Explosive (1910.109). (NIOSH, 2024). It may react vigorously with reducing agents, including hydrides, sulfides and nitrides. Incompatible with ozone, acids.
Belongs to the Following Reactive Group(s)
- Nitro, Nitroso, Nitrate, and Nitrite Compounds, Organic
Potentially Incompatible Absorbents
Use caution: Liquids with this reactive group classification have been
known to react with the
absorbents
listed below.
- Cellulose-Based Absorbents
- Expanded Polymeric Absorbents
Response Recommendations
Isolation and Evacuation
Excerpt from ERG Guide 113 [Flammable Materials (Wet / Desensitized Explosive)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area immediately for at least 100 meters (330 feet) in all directions.
LARGE SPILL: Consider initial evacuation for 500 meters (1/3 mile) in all directions.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 113 [Flammable Materials (Wet / Desensitized Explosive)]:
CARGO FIRE: DO NOT fight fire when fire reaches cargo! Cargo may EXPLODE! Stop all traffic and clear the area for at least 1600 meters (1 mile) in all directions and let burn. Do not move cargo or vehicle if cargo has been exposed to heat.
TIRE OR VEHICLE FIRE: Use plenty of water - FLOOD it! If water is not available, use CO2, dry chemical or dirt. If possible, and WITHOUT RISK, use unmanned master stream devices or monitor nozzles from maximum distance to prevent fire from spreading to cargo area. Pay special attention to tire fires as re-ignition may occur. Stand by, at a safe distance, with extinguisher ready for possible re-ignition. (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 113 [Flammable Materials (Wet / Desensitized Explosive)]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material.
SMALL SPILL: Flush area with large amounts of water.
LARGE SPILL: Wet down with water and dike for later disposal. KEEP "WETTED" PRODUCT WET BY SLOWLY ADDING FLOODING QUANTITIES OF WATER. (ERG, 2024)
Protective Clothing
Excerpt from ERG Guide 113 [Flammable Materials (Wet / Desensitized Explosive)]:
Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Excerpt from ERG Guide 113 [Flammable Materials (Wet / Desensitized Explosive)]:
Refer to the "General First Aid" section. (ERG, 2024)
Physical Properties
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight: data unavailable
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH:
75 mg/m3
[From NPG: Nitroglycerine]
(NIOSH, 2024)
AEGLs (Acute Exposure Guideline Levels)
No AEGL information available.
ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.
PACs (Protective Action Criteria)
Chemical |
PAC-1 |
PAC-2 |
PAC-3 |
Nitroglycerin (55-63-0)
|
0.1 mg/m3 |
2 mg/m3 |
75 mg/m3 |
(DOE, 2024)
Regulatory Information
EPA Consolidated List of Lists
Regulatory Name |
CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ |
EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
Nitroglycerin |
55-63-0 |
|
|
10 pounds |
313 |
P081 |
|
(EPA List of Lists, 2024)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
|
RELEASE |
THEFT |
SABOTAGE |
Chemical of Interest |
CAS Number |
Min Conc |
STQ |
Security Issue |
Min Conc |
STQ |
Security Issue |
Min Conc |
STQ |
Security Issue |
Nitroglycerine |
55-63-0 |
ACG |
5000 pounds |
explosive |
ACG |
400 pounds |
EXP/IEDP |
|
|
|
(CISA, 2007)
OSHA Process Safety Management (PSM) Standard List
No regulatory information available.
Alternate Chemical Names
- GLYCERYL TRINITRATE
- GLYCERYL TRINITRATE SOLUTION
- NG
- NITROGLYCERIN
- NITROGLYCERINE
- 1,2,3-PROPANETRIOL TRINITRATE
- TRINITROGLYCERINE