Print
Chemical Datasheet

CADMIUM NITRATE

5.1 - Oxidizer 6.1 - Poison

Chemical Identifiers

CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 10325-94-7
  • 3087
  • Oxidizer
  • Poison
  • CMN
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
data unavailable
General Description
Odorless white solid. Sinks in water. (USCG, 1999)

Hazards

Reactivity Alerts
Air & Water Reactions
Water soluble.
Fire Hazard
Special Hazards of Combustion Products: Toxic oxides of nitrogen and cadmium oxide fume may form in fires.

Behavior in Fire: Will increase intensity of fire when in contact with combustible material (USCG, 1999)
Health Hazard
Inhalation of fumes can produce coughing, chest constriction, headache, nausea, vomiting, pneumonitis. Chronic poisoning is characterized by emphysema and kidney injury. Ingestion causes gastrointestinal disturbance and severe toxic symptoms; both kidney and liver injuries may occur. Contact with eyes causes irritation. (USCG, 1999)
Reactivity Profile
Mixtures of metal/nonmetal nitrates with alkyl esters may explode, owing to the formation of alkyl nitrates; mixtures of a nitrate with phosphorus, tin (II) chloride, or other reducing agents may react explosively [Bretherick 1979 p. 108-109].
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below.

Response Recommendations

Isolation and Evacuation
Excerpt from 141 Polymerizable warning [Oxidizers - Toxic]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Excerpt from 141 Polymerizable warning [Oxidizers - Toxic]:

SMALL FIRE: Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.

LARGE FIRE: Flood fire area with water from a distance. Do not move cargo or vehicle if cargo has been exposed to heat. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2020)
Non-Fire Response
Excerpt from 141 Polymerizable warning [Oxidizers - Toxic]:

Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk.

SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.

LARGE SPILL: Dike far ahead of spill for later disposal. (ERG, 2020)
Protective Clothing
Rubber gloves; safety goggles; dust mask (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
INHALATION: remove patient to fresh air; seek medical attention.

INGESTION: give large amounts of water and induce vomiting; give milk or egg whites; seek medical attention.

EYES: flush with copious amounts of water for 15 min.; consult a physician.

SKIN: wash with soap and water. (USCG, 1999)

Physical Properties

Chemical Formula:
  • Cd(NO3)2
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: 138°F (USCG, 1999)
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 2.45 at 68°F (USCG, 1999) - Denser than water; will sink
Boiling Point: data unavailable
Molecular Weight: 308.47 (USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Cadmium nitrate (10325-94-7) 0.21 mg/m3 1.6 mg/m3 9.9 mg/m3
(DOE, 2018)

Regulatory Information

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Cadmium Compounds N078 & 313

(EPA List of Lists, 2022)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names