Print
Chemical Datasheet

CALCIUM CARBIDE

4.3 - Dangerous when wet

Chemical Identifiers

CAS Number UN/NA Number DOT Hazard Label USCG CHRIS Code
  • 75-20-7
  • 1402
  • Dangerous When Wet
  • CCB
NIOSH Pocket Guide International Chem Safety Card
none
  • CALCIUM CARBIDE
NFPA 704
Diamond Hazard Value Description
3
3 0
W
Blue Health 3 Can cause serious or permanent injury.
Red Flammability 3 Can be ignited under almost all ambient temperature conditions.
Yellow Instability 0 Normally stable, even under fire conditions.
White Special W Reacts violently or explosively with water.
Note: The NFPA value for instability is listed as "2" in the source data; however, the value has been corrected to "0" based on additional input from the manufacturer.
(NFPA, 2010)
General Description
Grayish-black irregular lump solid. Used to make acetylene and in steel manufacture.

Hazards

Reactivity Alerts
Air & Water Reactions
Reacts rapidly with water to generate the flammable gas acetylene and the base calcium hydroxide. Enough heat may be generated to ignite the gas [Jones, G.W. BM Report Invest. 3755 1944].
Fire Hazard
Behavior in Fire: If wet by water, highly flammable acetylene gas is formed. (USCG, 1999)
Health Hazard
Eye and skin irritation (USCG, 1999)
Reactivity Profile
CALCIUM CARBIDE is a reducing agent. May react vigorously with oxidizing materials. The powdered mixture of the acetylide and iron oxide and iron chloride burns violently upon ignition, producing molten iron. Calcium carbide incandesces with chlorine, bromine, or iodine at 245, 350, or 305°C., respectively, [Mellor, 1946, Vol. 5, 862]. The carbide burns incandescently when mixed and heated with lead difluoride, magnesium, hydrogen chloride, and tin (II) chloride, [Mellor, 1946, 1940, 1946, and 1941], respectively. Interaction of calcium carbide with methanol to give calcium methoxide is vigorous , but subject to an induction period of variable length. Once reaction starts, evolution of acetylene gas is very rapid, unpublished observations [Bretherick 1995]. Mixing calcium carbide with silver nitrate solutions forms silver acetylide, a highly sensitive explosive. Copper salt solutions would behave similarly, [Photogr. Sci. Eng., 1966, 10, 334]. The mixture of calcium carbide and sodium peroxide is explosive, as is calcium carbide and perchloryl fluoride as gases at 100-300°C.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

Response Recommendations

Isolation and Evacuation
Excerpt from 138 Polymerizable warning [Substances - Water-Reactive (Emitting Flammable Gases)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Excerpt from 138 Polymerizable warning [Substances - Water-Reactive (Emitting Flammable Gases)]:

DO NOT USE WATER OR FOAM.

SMALL FIRE: Dry chemical, soda ash, lime or sand.

LARGE FIRE: DRY sand, dry chemical, soda ash or lime or withdraw from area and let fire burn. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING METALS OR POWDERS (ALUMINUM, LITHIUM, MAGNESIUM, ETC.): Use dry chemical, DRY sand, sodium chloride powder, graphite powder or class D extinguishers; in addition, for Lithium you may use Lith-X® powder or copper powder. Also, see 170 Polymerizable warning.

FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2020)
Non-Fire Response
Excerpt from 138 Polymerizable warning [Substances - Water-Reactive (Emitting Flammable Gases)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. DO NOT GET WATER on spilled substance or inside containers.

SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Dike for later disposal; do not apply water unless directed to do so.

POWDER SPILL: Cover powder spill with plastic sheet or tarp to minimize spreading and keep powder dry. DO NOT CLEAN-UP OR DISPOSE OF, EXCEPT UNDER SUPERVISION OF A SPECIALIST. (ERG, 2020)
Protective Clothing
Chemical safety goggles and (for those exposed to unusually dusty operations) a respirator such as those approved by the U.S. Bureau of Mines for "nuisance dusts". (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
INHALATION OF DUST: remove from further exposure and call a doctor.

SKIN: wash with plenty of water.

EYES: flush with clean running water at an eye wash fountain for at least 15 min. and get medical attention. (USCG, 1999)

Physical Properties

Chemical Formula:
  • C2Ca
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: Not flammable (USCG, 1999)
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 2.22 at 64.4°F (USCG, 1999) - Denser than water; will sink
Boiling Point: data unavailable
Molecular Weight: 64.1 (USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Calcium carbide (75-20-7) 120 mg/m3 1300 mg/m3 7900 mg/m3
(DOE, 2018)

Regulatory Information

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Calcium carbide 75-20-7 10 pounds

(EPA List of Lists, 2022)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

Alternate Chemical Names