Chemical Datasheet
Chemical Identifiers
| UN/NA Number |
CAS Number |
CHRIS Code |
DOT Hazard Label |
|
|
|
none |
|
NFPA 704:
data unavailable
General Description
A clear colorless liquid with a sweet chloroform-like odor. Denser than water (density 1.991 g / cm3) and insoluble in water. Hence sinks in water. Boiling point 68°C. Vapors may cause illness if inhaled. Nonflammable. When exposed to high temperatures may emit toxic fumes. Used as a fire extinguishing agent.
Hazards
Reactivity Alerts
none
Air & Water Reactions
Insoluble in water.
Fire Hazard
Some of these materials may burn, but none ignite readily. Most vapors are heavier than air. Air/vapor mixtures may explode when ignited. Container may explode in heat of fire. (ERG, 2008)
Health Hazard
Toxic by ingestion. Vapors may cause dizziness or suffocation. Exposure in an enclosed area may be very harmful. Contact may irritate or burn skin and eyes. Fire may produce irritating and/or toxic gases. Runoff from fire control or dilution water may cause pollution. (ERG, 2008)
Reactivity Profile
BROMOCHLOROMETHANE is sensitive to light (may discolor). Incompatible with strong bases and strong oxidizing agents. Also incompatible with active metals, calcium, aluminum, magnesium, zinc and their alloys. Attacks some forms of plastics, rubber and coatings. (NTP, 1992).
Belongs to the Following Reactive Group(s)
- Halogenated Organic Compounds
Response Recommendations
Firefighting
Cool all affected containers with flooding quantities of water. Use water in flooding quantities as fog. Extinguish fire using agent suitable for type of surrounding fire. (Material itself does not burn or burns with difficulty.) Apply water from as far a distance as possible. Keep run-off water out of sewers and water sources. (AAR, 2003)
Non-Fire Response
Keep material out of water sources and sewers. Build dikes to contain flow as necessary. Attempt to stop leak if without undue personnel hazard. Apply water spray or mist to knock down vapors. Land spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid material. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Absorb bulk liquid with fly ash, cement powder, or commercial sorbents. Water spill: Use natural barriers or oil spill control booms to limit spill travel. Remove trapped material with suction hoses. (AAR, 2003)
Protective Clothing
Skin: Wear appropriate personal protective clothing to prevent skin contact.
Eyes: Wear appropriate eye protection to prevent eye contact.
Wash skin: The worker should immediately wash the skin when it becomes contaminated.
Remove: Work clothing that becomes wet or significantly contaminated should be removed and replaced.
Change: No recommendation is made specifying the need for the worker to change clothing after the work shift. (NIOSH, 2003)
_____Dupont Average Standardized Breakthrough Times_____
(for BROMOCHLOROMETHANE)
Tychem® Responder®
greater than 180 min. (concentration: 95+%)
Tychem® Responder® CSM
greater than 180 min. (concentration: 95+%) (DuPont, 2008)
Copyrighted information of E.I. du Pont de Nemours and Company. Tychem® is a registered trademark of E.I. du Pont de Nemours and Company.
First Aid
EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.
SKIN: IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. IMMEDIATELY call a hospital or poison control center even if no symptoms (such as redness or irritation) develop. IMMEDIATELY transport the victim to a hospital for treatment after washing the affected areas.
INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. If symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the victim to a hospital. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater than or equal to that advised under Protective Clothing.
INGESTION: DO NOT INDUCE VOMITING. Corrosive chemicals will destroy the membranes of the mouth, throat, and esophagus and volatile chemicals have a high risk of being aspirated into the victim's lungs during vomiting. Thus, the risk of increasing the medical problems by inducing vomiting of a volatile corrosive chemical is very high. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. IMMEDIATELY transport the victim to a hospital. If the victim is convulsing or unconscious, do not give anything by mouth, ensure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. IMMEDIATELY transport the victim to a hospital. (NTP, 1992)
Physical Properties
Flash Point: data unavailable
Lower Explosive Limit: data unavailable
Upper Explosive Limit: data unavailable
Autoignition Temperature: data unavailable
Melting Point:
-126.0 ° F
(NTP, 1992)
Vapor Pressure:
117.0 mm Hg
at 68.0 ° F
(NTP, 1992)
Vapor Density:
4.46
(NTP, 1992)
Specific Gravity:
1.93
at 77.0 ° F
(NTP, 1992)
Boiling Point:
154.0 ° F
at 760 mm Hg
(NTP, 1992)
Molecular Weight:
129.39
(NTP, 1992)
Water Solubility:
1-5 mg/mL
at 68° F
(NTP, 1992)
| TEEL-1 |
TEEL-2 |
TEEL-3 |
| 600.0 ppm |
1000.0 ppm |
2000.0 ppm |
| (SCAPA, 2008) |
IDLH:
2000.0 ppm
(NIOSH, 2003)
Regulatory Information
Regulatory Names:
none
CAA RMP:
Not a regulated chemical.
CERCLA:
Not a regulated chemical.
EHS (EPCRA 302):
Not a regulated chemical.
TRI (EPCRA 313):
Not a regulated chemical.
RCRA Chemical Code:
none
Alternate Chemical Names
- BROMOCHLOROMÉTHANE (DOT FRENCH)
- BROMOCLOROMETANO (DOT SPANISH)
- CB
- CBM
- CHLOROBROMOMETHANE
- FLUOROCARBON 1011
- HALON 1011
- HALON® 1011
- METHANE, BROMOCHLORO-
- METHYL CHLOROBROMIDE
- METHYLENE CHLOROBROMIDE
- MIL-B-4394-B
- MONO-CHLORO-MONO-BROMO-METHANE
- MONOCHLOROMONOBROMOMETHANE
- UN 1887