Chemical Datasheet
TIGLIC ACID, [CORROSIVE SOLID] |
Chemical Identifiers
UN/NA Number - The United Nations-North America number (also called UN number or DOT number). 4-digit number identifying an individual chemical or group of chemicals with similar characteristics. Required on shipping papers; often shown on placards or labels. This numbering system was developed by the U.S. Department of Transportation, and then became the UN standard system for classifying hazardous materials.
CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.
CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.
DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.
NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and reactivity hazards, along with special hazards such as water- and air-reactivity. (The NFPA 704 diamond is also shown at the top of the datasheet.) See a guide to the NFPA diamond.
General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.
List of data sources.
CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.
CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.
DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.
NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and reactivity hazards, along with special hazards such as water- and air-reactivity. (The NFPA 704 diamond is also shown at the top of the datasheet.) See a guide to the NFPA diamond.
General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.
List of data sources.
| UN/NA Number | CAS Number | CHRIS Code | DOT Hazard Label |
|---|---|---|---|
|
none |
|
NFPA 704:
data unavailable
General Description
A white lustrous flaked solid with a fruity or spicy odor. About the same density as water and slightly soluble in water. May burn if heated to high temperatures. May severely irritate skin, eyes, lungs or mucous membranes.
Hazards
Reactivity Alerts - Special alerts if the chemical is especially reactive
(see list of reactivity alerts).
Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.
Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).
Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).
Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).
Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.
List of data sources.
Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.
Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).
Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).
Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).
Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.
List of data sources.
Reactivity Alerts
none
Air & Water Reactions
Slightly soluble in water.
Fire Hazard
Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. Some are oxidizers and may ignite combustibles (wood, paper, oil, clothing, etc.). Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated. (ERG, 2008)
Health Hazard
TOXIC; inhalation, ingestion or skin contact with material may cause severe injury or death. Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact. Effects of contact or inhalation may be delayed. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2008)
Reactivity Profile
TIGLIC ACID is a carboxylic acid. Carboxylic acids donate hydrogen ions if a base is present to accept them. They react in this way with all bases, both organic (for example, the amines) and inorganic. Their reactions with bases, called "neutralizations", are accompanied by the evolution of substantial amounts of heat. Neutralization between an acid and a base produces water plus a salt. Carboxylic acids in aqueous solution and liquid or molten carboxylic acids can react with active metals to form gaseous hydrogen and a metal salt. Such reactions occur in principle for solid carboxylic acids as well, but are slow if the solid acid remains dry. Even "insoluble" carboxylic acids may absorb enough water from the air and dissolve sufficiently in it to corrode or dissolve iron, steel, and aluminum parts and containers. Carboxylic acids, like other acids, react with cyanide salts to generate gaseous hydrogen cyanide. The reaction is slower for dry, solid carboxylic acids. Insoluble carboxylic acids react with solutions of cyanides to cause the release of gaseous hydrogen cyanide. Flammable and/or toxic gases and heat are generated by the reaction of carboxylic acids with diazo compounds, dithiocarbamates, isocyanates, mercaptans, nitrides, and sulfides. Carboxylic acids, especially in aqueous solution, also react with sulfites, nitrites, thiosulfates (to give H2S and SO3), dithionites (SO2), to generate flammable and/or toxic gases and heat. Their reaction with carbonates and bicarbonates generates a harmless gas (carbon dioxide) but still heat. Like other organic compounds, carboxylic acids can be oxidized by strong oxidizing agents and reduced by strong reducing agents. These reactions generate heat. A wide variety of products is possible. Like other acids, carboxylic acids may initiate polymerization reactions; like other acids, they often catalyze (increase the rate of) chemical reactions.
Belongs to the Following Reactive Group(s)
Response Recommendations
Firefighting - Response recommendations if the chemical is on fire (or near a fire).
Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).
Protective Clothing - Recommendations for protective gear and, in some cases, a table of breakthrough times for protective materials.
First Aid - Recommended first aid treatment for people exposed to the chemical.
List of data sources.
Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).
Protective Clothing - Recommendations for protective gear and, in some cases, a table of breakthrough times for protective materials.
First Aid - Recommended first aid treatment for people exposed to the chemical.
List of data sources.
Firefighting
Extinguish fire using agent suitable for type of surrounding fire. (Material itself does not burn or burns with difficulty.) Use water in flooding quantities as fog. Use foam, dry chemical, or carbon dioxide. Keep run-off water out of sewers and water sources. (AAR, 2003)
Non-Fire Response
Build dikes to contain flow as necessary. Land spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid material. Cover solids with a plastic sheet to prevent dissolving in rain or fire fighting water. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Neutralize with vinegar or other dilute acid. Absorb bulk liquid with fly ash or cement powder. Water spill: Use natural barriers or oil spill control booms to limit spill travel. Neutralize with dilute acid. (AAR, 2003)
Protective Clothing
Avoid breathing vapors or dusts. Avoid breathing fumes from burning material. Wear appropriate chemical protective gloves, boots and goggles. Wear positive pressure self-contained breathing apparatus. Wet spilled material before picking it up. Do not handle broken packages unless wearing appropriate personal protective equipment. (AAR, 2003)
First Aid
Move victim to fresh air; call emergency medical care. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. In case of contact with material, immediately flush skin or eyes with running water for at least 15 minutes. Remove and isolate contaminated clothing and shoes at the site. (AAR, 2003)
Physical Properties
This section contains physical properties, flammability limits, and toxic thresholds for this chemical (see
definitions of each property).
More property data is available for common chemicals.
See also the Levels of Concern guide for information on AEGLs, ERPGs, PACs, and IDLH values.
List of data sources.
See also the Levels of Concern guide for information on AEGLs, ERPGs, PACs, and IDLH values.
List of data sources.
| Molecular Formula: |
|
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density: data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight: data unavailable
Water Solubility: data unavailable
IDLH: data unavailable
AEGLs (Acute Exposure Guideline Levels)
No AEGL information available.ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.PACs (Protective Action Criteria)
No PAC information available.Regulatory Information
Regulatory Names - Names under which this chemical is regulated under several U.S. federal laws: CAA (Clean Air Act of 1990), CERCLA (Comprehensive Environmental Response, Compensation, and Liability Act of 1980, also known as Superfund), EPCRA (Emergency Planning and Community Right-to-Know Act, also known as SARA Title III), and RCRA (Resource Conservation and Recovery Act of 1976).
CAA RMP - Indicates whether this chemical is regulated under Section 112(r) of the Clean Air Act, which lists about 100 toxic, flammable, or explosive hazardous substances. (Section 112(r) mandates the Risk Management Plan regulations.) For listed chemicals, the Threshold Quantity (from 40 CFR 68) is also shown. Facilities that use more than the threshold quantity of a listed chemical in a process are subject to the CAA accidental release prevention provisions.
CERCLA - Indicates whether this chemical is listed as a hazardous substance under CERCLA. For listed chemicals, the Reportable Quantity (from 40 CFR 302) is also shown. Facilities that spill more than the reportable quantity of a listed chemical must report it to federal, state, and local governments.
EHS (EPCRA 302) - Indicates whether this chemical is listed as an Extremely Hazardous Substance under Section 302 of EPCRA. For listed chemicals, the Threshold Planning Quantity (from 40 CFR 355) is also shown. Facilities that store more than the threshold quantity of an EHS chemical must meet the reporting, community right-to-know, and emergency planning requirements of EPCRA.
TRI (EPCRA 313) - Indicates whether this chemical is listed as a toxic chemical under Section 313 (Toxics Release Inventory) of EPCRA. Facilities that manufacture, store, or use significant amounts of Section 313 chemicals may be required to submit annual reports about any releases into the environment (see 40 CFR 372).
RCRA Chemical Code - 4-character identification code assigned to this substance under RCRA.
List of data sources.
CAA RMP - Indicates whether this chemical is regulated under Section 112(r) of the Clean Air Act, which lists about 100 toxic, flammable, or explosive hazardous substances. (Section 112(r) mandates the Risk Management Plan regulations.) For listed chemicals, the Threshold Quantity (from 40 CFR 68) is also shown. Facilities that use more than the threshold quantity of a listed chemical in a process are subject to the CAA accidental release prevention provisions.
CERCLA - Indicates whether this chemical is listed as a hazardous substance under CERCLA. For listed chemicals, the Reportable Quantity (from 40 CFR 302) is also shown. Facilities that spill more than the reportable quantity of a listed chemical must report it to federal, state, and local governments.
EHS (EPCRA 302) - Indicates whether this chemical is listed as an Extremely Hazardous Substance under Section 302 of EPCRA. For listed chemicals, the Threshold Planning Quantity (from 40 CFR 355) is also shown. Facilities that store more than the threshold quantity of an EHS chemical must meet the reporting, community right-to-know, and emergency planning requirements of EPCRA.
TRI (EPCRA 313) - Indicates whether this chemical is listed as a toxic chemical under Section 313 (Toxics Release Inventory) of EPCRA. Facilities that manufacture, store, or use significant amounts of Section 313 chemicals may be required to submit annual reports about any releases into the environment (see 40 CFR 372).
RCRA Chemical Code - 4-character identification code assigned to this substance under RCRA.
List of data sources.
Regulatory Names:
none
CAA RMP:
Not a regulated chemical.
CERCLA:
Not a regulated chemical.
EHS (EPCRA 302):
Not a regulated chemical.
TRI (EPCRA 313):
Not a regulated chemical.
RCRA Chemical Code:
none
Alternate Chemical Names
This section provides a listing of alternate names for this chemical, including trade names, synonyms, and foreign names.
- (E)-2,3-DIMETHYLACRYLIC ACID
- (E)-2-METHYL-2-BUTENOIC ACID
- (E)-2-METHYLCROTONIC ACID
- (E)-ALPHA-METHYLCROTONIC ACID
- 2-BUTENOIC ACID, 2-METHYL-, (E)-
- CEVADIC ACID
- CROTONIC ACID, 2-METHYL-, (E)-
- TIGLIC ACID
- TIGLINIC ACID
- TRANS-2,3-DIMETHYLACRYLIC ACID
- TRANS-2-METHYL-2-BUTENOIC ACID
- TRANS-2-METHYLCROTONIC ACID
- TRANS-ALPHA,BETA-DIMETHYLACRYLIC ACID