Chemical Datasheet
PHENOL SOLUTION, [AQUEOUS] |
|
|||||||||
Chemical Identifiers
UN/NA Number - The United Nations-North America number (also called UN number or DOT number). 4-digit number identifying an individual chemical or group of chemicals with similar characteristics. Required on shipping papers; often shown on placards or labels. This numbering system was developed by the U.S. Department of Transportation, and then became the UN standard system for classifying hazardous materials.
CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.
CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.
DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.
NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and reactivity hazards, along with special hazards such as water- and air-reactivity. (The NFPA 704 diamond is also shown at the top of the datasheet.) See a guide to the NFPA diamond.
General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.
List of data sources.
CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.
CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.
DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.
NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and reactivity hazards, along with special hazards such as water- and air-reactivity. (The NFPA 704 diamond is also shown at the top of the datasheet.) See a guide to the NFPA diamond.
General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.
List of data sources.
| UN/NA Number | CAS Number | CHRIS Code | DOT Hazard Label |
|---|---|---|---|
|
none |
|
| NFPA 704: |
|
General Description
White crystalline mass dissolved in an aqueous solution. Solution may be colorless to slightly pink in color with a distinctive phenol odor; sharp burning taste. Aqueous solution will be acidic and act as such. Toxic by ingestion, inhalation and skin absorption; strong irritant to tissues.
Hazards
Reactivity Alerts - Special alerts if the chemical is especially reactive
(see list of reactivity alerts).
Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.
Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).
Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).
Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).
Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.
List of data sources.
Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.
Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).
Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).
Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).
Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.
List of data sources.
Reactivity Alerts
none
Air & Water Reactions
Water soluble.
Fire Hazard
Combustible material: may burn but does not ignite readily. When heated, vapors may form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated. Runoff may pollute waterways. Substance may be transported in a molten form. (ERG, 2008)
Health Hazard
TOXIC; inhalation, ingestion or skin contact with material may cause severe injury or death. Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact. Effects of contact or inhalation may be delayed. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2008)
Reactivity Profile
Phenols do not behave as organic alcohols, as one might guess from the presence of a hydroxyl (-OH) group in their structure. Instead, they react as weak organic acids. Phenols and cresols are much weaker as acids than common carboxylic acids (phenol has Ka = 1.3 x 10^[-10]). These materials are incompatible with strong reducing substances such as hydrides, nitrides, alkali metals, and sulfides. Flammable gas (H2) is often generated, and the heat of the reaction may ignite the gas. Heat is also generated by the acid-base reaction between phenols and bases. Such heating may initiate polymerization of the organic compound. Phenols are sulfonated very readily (for example, by concentrated sulfuric acid at room temperature). The reactions generate heat. Phenols are also nitrated very rapidly, even by dilute nitric acid. Phenol may explode in contact with peroxodisulfuric acid (D’Ans, J. Ber., 1910, 43, 1880; Z. Anorg. Chem., 1911, 73, 1911.) or peroxomonosulfuric acid. (Sidgwick, 1950, 939)
Belongs to the Following Reactive Group(s)
Response Recommendations
Firefighting - Response recommendations if the chemical is on fire (or near a fire).
Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).
Protective Clothing - Recommendations for protective gear and, in some cases, a table of breakthrough times for protective materials.
First Aid - Recommended first aid treatment for people exposed to the chemical.
List of data sources.
Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).
Protective Clothing - Recommendations for protective gear and, in some cases, a table of breakthrough times for protective materials.
First Aid - Recommended first aid treatment for people exposed to the chemical.
List of data sources.
Firefighting
SMALL FIRE: Dry chemical, CO2 or water spray.
LARGE FIRE: Dry chemical, CO2, alcohol-resistant foam or water spray. Move containers from fire area if you can do it without risk. Dike fire-control water for later disposal; do not scatter the material.
FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2008)
LARGE FIRE: Dry chemical, CO2, alcohol-resistant foam or water spray. Move containers from fire area if you can do it without risk. Dike fire-control water for later disposal; do not scatter the material.
FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2008)
Non-Fire Response
ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2008)
Protective Clothing
_____Dupont Average Standardized Breakthrough Times_____
(for PHENOL)
Tychem® BR
greater than 480 min. (concentration: 85+%)
Tychem® CPF2
greater than 480 min. (concentration: 85%)
Tychem® CPF3
85 min. (concentration: 85-90%%)
Tychem® CPF4
greater than 480 min. (concentration: 85%)
Tychem® F
238 min. (concentration: 85%)
Tychem® LV
greater than 480 min. (concentration: 85+%)
Tychem® PVC
15 min. (concentration: 95+%)
Tychem® QC
immediate (less than 10 min.) (concentration: 85%)
Tychem® QC for Corrections
immediate (less than 10 min.) (concentration: 85%)
Tychem® Reflector®
greater than 480 min. (concentration: 89%)
Tychem® Responder®
greater than 480 min. (concentration: 85%)
Tychem® Responder® CSM
greater than 480 min. (concentration: 85%)
Tychem® SL
greater than 480 min. (concentration: 85%)
Tychem® ThermoPro
238 min. (concentration: 85-90%)
Tychem® TK
greater than 480 min. (concentration: 85+%) (DuPont, 2008)
Copyrighted information of E.I. du Pont de Nemours and Company. Tychem® is a registered trademark of E.I. du Pont de Nemours and Company.
First Aid
Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. For minor skin contact, avoid spreading material on unaffected skin. Keep victim warm and quiet. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. (ERG, 2008)
Physical Properties
This section contains physical properties, flammability limits, and toxic thresholds for this chemical (see
definitions of each property).
More property data is available for common chemicals.
Guide to toxic levels of concern (AEGLs, ERPGs, TEELs, and IDLH).
List of data sources.
Guide to toxic levels of concern (AEGLs, ERPGs, TEELs, and IDLH).
List of data sources.
| Molecular Formula: |
|
Flash Point: data unavailable
Lower Explosive Limit: data unavailable
Upper Explosive Limit: data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density: data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight: data unavailable
Water Solubility: data unavailable
AEGL:
data unavailable
| ERPG-1 | ERPG-2 | ERPG-3 |
|---|---|---|
| 10.0 ppm | 50.0 ppm | 200.0 ppm |
| (AIHA, 2008) | ||
TEEL:
data unavailable
IDLH:
250.0 ppm
(as phenol)
(NIOSH, 2003)
Regulatory Information
Regulatory Names - Names under which this chemical is regulated under several U.S. federal laws: CAA (Clean Air Act of 1990), CERCLA (Comprehensive Environmental Response, Compensation, and Liability Act of 1980, also known as Superfund), EPCRA (Emergency Planning and Community Right-to-Know Act, also known as SARA Title III), and RCRA (Resource Conservation and Recovery Act of 1976).
CAA RMP - Indicates whether this chemical is regulated under Section 112(r) of the Clean Air Act, which lists about 100 toxic, flammable, or explosive hazardous substances. (Section 112(r) mandates the Risk Management Plan regulations.) For listed chemicals, the Threshold Quantity (from 40 CFR 68) is also shown. Facilities that use more than the threshold quantity of a listed chemical in a process are subject to the CAA accidental release prevention provisions.
CERCLA - Indicates whether this chemical is listed as a hazardous substance under CERCLA. For listed chemicals, the Reportable Quantity (from 40 CFR 302) is also shown. Facilities that spill more than the reportable quantity of a listed chemical must report it to federal, state, and local governments.
EHS (EPCRA 302) - Indicates whether this chemical is listed as an Extremely Hazardous Substance under Section 302 of EPCRA. For listed chemicals, the Threshold Planning Quantity (from 40 CFR 355) is also shown. Facilities that store more than the threshold quantity of an EHS chemical must meet the reporting, community right-to-know, and emergency planning requirements of EPCRA.
TRI (EPCRA 313) - Indicates whether this chemical is listed as a toxic chemical under Section 313 (Toxics Release Inventory) of EPCRA. Facilities that manufacture, store, or use significant amounts of Section 313 chemicals may be required to submit annual reports about any releases into the environment (see 40 CFR 372).
RCRA Chemical Code - 4-character identification code assigned to this substance under RCRA.
CAA RMP - Indicates whether this chemical is regulated under Section 112(r) of the Clean Air Act, which lists about 100 toxic, flammable, or explosive hazardous substances. (Section 112(r) mandates the Risk Management Plan regulations.) For listed chemicals, the Threshold Quantity (from 40 CFR 68) is also shown. Facilities that use more than the threshold quantity of a listed chemical in a process are subject to the CAA accidental release prevention provisions.
CERCLA - Indicates whether this chemical is listed as a hazardous substance under CERCLA. For listed chemicals, the Reportable Quantity (from 40 CFR 302) is also shown. Facilities that spill more than the reportable quantity of a listed chemical must report it to federal, state, and local governments.
EHS (EPCRA 302) - Indicates whether this chemical is listed as an Extremely Hazardous Substance under Section 302 of EPCRA. For listed chemicals, the Threshold Planning Quantity (from 40 CFR 355) is also shown. Facilities that store more than the threshold quantity of an EHS chemical must meet the reporting, community right-to-know, and emergency planning requirements of EPCRA.
TRI (EPCRA 313) - Indicates whether this chemical is listed as a toxic chemical under Section 313 (Toxics Release Inventory) of EPCRA. Facilities that manufacture, store, or use significant amounts of Section 313 chemicals may be required to submit annual reports about any releases into the environment (see 40 CFR 372).
RCRA Chemical Code - 4-character identification code assigned to this substance under RCRA.
Regulatory Names:
none
CAA RMP:
Not a regulated chemical.
CERCLA:
Not a regulated chemical.
EHS (EPCRA 302):
Not a regulated chemical.
TRI (EPCRA 313):
Not a regulated chemical.
RCRA Chemical Code:
none
Alternate Chemical Names
This section provides a listing of alternate names for this chemical, including trade names, synonyms, and foreign names.
- FENOL, EN SOLUCIÓN (DOT SPANISH)
- LIQUID TAR ACID, [CONTAINING > 50 % PHENOL]
- PHENOL SOLUTION
- PHÉNOL, EN SOLUTION (DOT FRENCH)